TY - GEN
T1 - Wind Generator design and testing: A lab scale 5×5 m2 WG for floating wind turbines
AU - Mikkelsen, Robert F.
AU - Pierella, Fabio
AU - Frydenberg, Gustav S.
AU - Enevoldsen, Karen
AU - Nielsen, Ida
AU - Møller, Rene
AU - Thorsen, Gunhild R.
AU - Hannesdóttir, Ásta
AU - Riva, Riccardo
AU - Babu, Ramakrishnan A.
AU - Johannesen, Ignacio P.
AU - Bredmose, Henrik
PY - 2026
Y1 - 2026
N2 - A new 5×5 m2 wind generator (WG) comprising 25 individually controlled 1 m2 blower units has been designed, built and tested as part of the Danish FloatLab project for combined wind-wave laboratory testing of floating wind turbines (FWT). The WG targets a maximum wind speed of 5 m/s with a small-scale turbulence intensity of TI ≃ 2–3%, and is scaled at 1:70 to support the testing of a model turbine representing the IEA Wind 22 MW Reference Wind Turbine in a 20×30 m2 wave basin. Individual servo control of all 25 fan units enables the generation of large-scale synthetic atmospheric turbulence equivalent to a 70×70 m2 footprint at full scale, including wind shear and spatially varying turbulent fluctuations. The WG was validated through a three-stage test campaign: single-unit characterization, 2×2 array testing with harmonic loading and wind shear, and full 5×5 array testing against the targeted wind regimes NSS1–5. Hot-wire measurements at 1D and 1.5D downstream of the WG outlet confirm that the generated turbulence closely matches the theoretical Mann spectrum up to 0.1 Hz, with increased spectral decay at higher frequencies attributed to amplitude dissipation at shorter wavelengths. Compensation strategies for this dissipation are identified as a priority for future work.
AB - A new 5×5 m2 wind generator (WG) comprising 25 individually controlled 1 m2 blower units has been designed, built and tested as part of the Danish FloatLab project for combined wind-wave laboratory testing of floating wind turbines (FWT). The WG targets a maximum wind speed of 5 m/s with a small-scale turbulence intensity of TI ≃ 2–3%, and is scaled at 1:70 to support the testing of a model turbine representing the IEA Wind 22 MW Reference Wind Turbine in a 20×30 m2 wave basin. Individual servo control of all 25 fan units enables the generation of large-scale synthetic atmospheric turbulence equivalent to a 70×70 m2 footprint at full scale, including wind shear and spatially varying turbulent fluctuations. The WG was validated through a three-stage test campaign: single-unit characterization, 2×2 array testing with harmonic loading and wind shear, and full 5×5 array testing against the targeted wind regimes NSS1–5. Hot-wire measurements at 1D and 1.5D downstream of the WG outlet confirm that the generated turbulence closely matches the theoretical Mann spectrum up to 0.1 Hz, with increased spectral decay at higher frequencies attributed to amplitude dissipation at shorter wavelengths. Compensation strategies for this dissipation are identified as a priority for future work.
U2 - 10.1088/1742-6596/3224/8/082047
DO - 10.1088/1742-6596/3224/8/082047
M3 - Article in proceedings
T3 - Journal of Physics: Conference Series
BT - Proceedings of The Science of Making Torque from Wind (TORQUE 2026)
PB - IOP Publishing
T2 - 2026 The Science of making Torque from wind
Y2 - 3 June 2026 through 5 June 2026
ER -