The knowledge of the modal capacitance and electro-mechanical coupling factor is essential for a proper design of systems with embedded piezoelectric transducers and materials. In light of this, this paper presents two indirect methods for measuring the piezoelectric modal capacitance and a method to estimate the modal electro-mechanical coupling factor. All methods rely on simple vibration measurements of the structure with the piezoelectric transducer connected to a proper shunt impedance, thus avoiding measurements of piezoelectric current and voltage by expensive equipment. For the modal electro-mechanical coupling factor, the proposed method guarantees reduced uncertainty compared to traditional experimental estimation procedures. Upon introduction of the underlying theory, the paper experimentally demonstrates the reliability and effectiveness of the methods by comparison with well-established procedures.
Original language | English |
---|---|
Article number | 107350 |
Journal | Mechanical Systems and Signal Processing |
Volume | 151 |
Number of pages | 16 |
ISSN | 0888-3270 |
DOIs | |
Publication status | Published - 2021 |
Keywords
- Vibration control
- Modal capacitance
- Coupling factor
- Piezoelectric shunt
- Negative capacitance
- Resonant shunt