Variation in the measurement of DNA damage by comet assay measured by the ECVAG dagger inter-laboratory validation trial

  • Lykke Forchhammer
  • , Clara Johansson
  • , Steffen Loft
  • , Lennart Møller
  • , Roger W. L. Godschalk
  • , Sabine A. S. Langie
  • , George D. D. Jones
  • , Rachel W. L. Kwok
  • , Andrew R. Collins
  • , Amaya Azqueta
  • , David H. Phillips
  • , Osman Sozeri
  • , Maciej Stepnik
  • , Jadwiga Palus
  • , Ulla Birgitte Vogel
  • , Hakan Wallin
  • , Michael N. Routledge
  • , Catherine Handforth
  • , Alessandra Allione
  • , Giuseppe Matullo
  • Joao Paulo Teixeira, Solange Costa, Patrizia Riso, Marisa Porrini, Peter Møller

Research output: Contribution to journal › Journal article › Research › peer-review

Abstract

The comet assay has become a popular method for the assessment of DNA damage in biomonitoring studies and genetic toxicology. However, few studies have addressed the issue of the noted inter-laboratory variability of DNA damage measured by the comet assay. In this study, 12 laboratories analysed the level of DNA damage in monocyte-derived THP-1 cells by either visual classification or computer-aided image analysis of pre-made slides, coded cryopreserved samples of cells and reference standard cells (calibration curve samples). The reference standard samples were irradiated with ionizing radiation (0-10 Gy) and used to construct a calibration curve to calculate the number of lesions per 10(6) base pair. All laboratories detected dose-response relationships in the coded samples irradiated with ionizing radiation (1.5-7 Gy), but there were overt differences in the level of DNA damage reported by the different laboratories as evidenced by an inter-laboratory coefficient of variation (CV) of 47%. Adjustment of the primary comet assay end points by a calibration curve prepared in each laboratory reduced the CV to 28%, a statistically significant reduction (P <0.05, Levene's test). A large fraction of the inter-laboratory variation originated from differences in image analysis, whereas the intra-laboratory variation was considerably smaller than the variation between laboratories. In summary, adjustment of primary comet assay results by reference standards reduces inter-laboratory variation in the level of DNA damage measured by the alkaline version of the comet assay.
Original languageEnglish
JournalMutagenesis
Volume25
Issue number2
Pages (from-to)113-123
ISSN0267-8357
DOIs
Publication statusPublished - 2010