Skip to main navigation Skip to search Skip to main content

Validation of Transverse Oscillation Vector Velocity Estimation In-Vivo

  • Kristoffer Lindskov Hansen
  • , Jesper Udesen
  • , Carsten Thomsen
  • , Jørgen Arendt Jensen
  • , Michael Bachmann Nielsen
    • Copenhagen University Hospital Herlev and Gentofte

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    Abstract

    Conventional Doppler methods for blood velocity estimation only estimate the velocity component along the ultrasound (US) beam direction. This implies that a Doppler angle under examination close to 90deg results in unreliable information about the true blood direction and blood velocity. The novel method Transverse Oscillation (TO), which combines estimates of the axial and the transverse velocity components in the scan plane, makes it possible to estimate the vector velocity of the blood regardless of the Doppler angle. The present study evaluates the TO method with magnetic resonance angiography (MRA) by comparing in-vivo measurements of stroke volume (SV) obtained from the right common carotid artery. Angle of insonation was 90deg for the TO measurements. Eleven healthy volunteers were scanned with the TO method and MRA. The overall results were as follows: mean SV +/- STD for TO: 5.5 ml +/- 1.7 ml and for MRA: 5.8 ml +/- 2.0 ml with the full range for TO: 3.4 ml - 9.5 ml and for MRA 3.0 ml - 10.8 ml. The correlation between the SV estimated by TO and MRA was 0.91 (p < 0.01; 95 % CI: 0.69 to 0.98) with the equation for the line of regression MRA = 1.1ldrTO - 0.4. A Bland-Altman plot was constructed where the mean difference was 0.2 ml with limits of agreement at -1.4 ml and 1.9 ml (95 % CI for mean difference: -0.3 ml to 0.8 ml). The strong correlation and the low mean difference between the TO method and MRA indicates that reliable vector velocity estimates can be obtained in vivo using the presented angle independent 2-D vector velocity method. The results give reason to believe that the TO method can be a useful alternative to conventional Doppler systems bringing forth new information to the US examination of blood flow.
    Original languageEnglish
    Title of host publicationUltrasonics Symposium, 2007. IEEE
    Place of PublicationNew York, NY,
    PublisherIEEE
    Publication date2007
    Pages1093-1096
    ISBN (Print)978-1-4244-1384-3
    DOIs
    Publication statusPublished - 2007
    Event2007 IEEE Ultrasonics Symposium - New York, United States
    Duration: 28 Oct 200731 Oct 2007
    https://ieeexplore.ieee.org/xpl/conhome/4409572/proceeding

    Conference

    Conference2007 IEEE Ultrasonics Symposium
    Country/TerritoryUnited States
    CityNew York
    Period28/10/200731/10/2007
    Internet address

    Fingerprint

    Dive into the research topics of 'Validation of Transverse Oscillation Vector Velocity Estimation In-Vivo'. Together they form a unique fingerprint.

    Cite this