Tunable intra-cavity SHG of CW Ti:Sapphire lasers around 785 nm and 810 nm in BiBO-crystals

Morten Thorhauge, Jesper Liltorp Mortensen, Peter Tidemand-Lichtenberg, Preben Buchhave

Research output: Contribution to journalJournal articleResearchpeer-review

765 Downloads (Pure)

Abstract

Phasematch curves as well as sensitivity to angular and wavelength misalignment for generation of second-harmonic of 785 nm and 810 nm in Bi3BO6 crystal was calculated. Measurements were done for intra-cavity CW SHG in a Ti:Sapphire laser. The BiBO crystal was found to be excellent for this application. Temperature dependance was uncritical for both crystals, while power stability was good. Maximum blue output was 53 mW at 392 nm and 100 mW at 405 nm; corresponding to pump-to-blue optical conversion efficiencies of 0.96% and 1.82% respectively.
Original languageEnglish
JournalOptics Express
Volume14
Issue number6
Pages (from-to)2283-2288
ISSN1094-4087
DOIs
Publication statusPublished - 2006

Fingerprint

Dive into the research topics of 'Tunable intra-cavity SHG of CW Ti:Sapphire lasers around 785 nm and 810 nm in BiBO-crystals'. Together they form a unique fingerprint.