The Principle of Pooled Calibrations and Outlier Retainment Elucidates Optimum Performance of Ion Chromatography

Jens Enevold Thaulov Andersen, Maria Mikolajczak, Katarzyna Olga Wojtachnio-Zawada, Henrik Vigan Nicolajsen

Research output: Contribution to conferenceConference abstract for conferenceResearchpeer-review

201 Downloads (Pure)

Abstract

A new principle of statistical data treatment is presented. Since the majority of scientists and costumers are interested in determination of the true amount of analyte in real samples, the focus of attention should be directed towards the concept of accuracy rather than precision. By exploiting the principle of pooled calibrations retaining all outliers it was possible to obtain full correspondence between uncertainty of calibration and uncertainty of repetition, which for the first time evidences statistical control in experiments of ion chromatography. Chloride, bromide and oxalate were determined at a high number of repetitions in standards containing different anions. The method was capable of baseline separation of 17 different anions. It was found that the limit of quantification (LOQ) was significantly underestimated by up to an order of magnitude with respect to determination of concentration of unknowns. The concept of lower-limit of analysis (LLA) and upper-limit of analysis (ULA) were found to provide more acceptable limits with respect to reliable analysis at a limited number of repetitions. These findings comply with earlier investigations of method validations where it was found that the principle of pooled calibrations provides a more realistic picture of the analytical performance with the drawback however, that generally higher levels of uncertainties should be accepted, as compared to contemporary literature values. The implications to the science of analytical chemistry in general and to method validations in particular are discussed.
Original languageEnglish
Publication date2012
Number of pages1
Publication statusPublished - 2012
EventEuroanalysis 16: Challenges in Modern Analytical Chemistry - Europe, Belgrade, Serbia
Duration: 11 Sep 201115 Sep 2011

Conference

ConferenceEuroanalysis 16
LocationEurope
CountrySerbia
CityBelgrade
Period11/09/201115/09/2011

Fingerprint Dive into the research topics of 'The Principle of Pooled Calibrations and Outlier Retainment Elucidates Optimum Performance of Ion Chromatography'. Together they form a unique fingerprint.

  • Euroanalysis 16

    Jens Andersen (Speaker)

    11 Sep 201115 Sep 2011

    Activity: Talks and presentationsConference presentations

    File

Cite this