The effect of a personalized ventilation system on perceived air quality and SBS symptoms

Jan Kaczmarczyk, Q. Zeng, Arsen Krikor Melikov, Povl Ole Fanger

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Abstract

Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled. Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p
Original languageEnglish
Title of host publicationProceedings of Indoor Air 2002
Publication date2002
Publication statusPublished - 2002
Event9th International Conference on Indoor Air Quality and Climate - Monterey, CA, United States
Duration: 30 Jun 20025 Jul 2002
Conference number: 9
http://www.indair.org/index_files/Page325.htm

Conference

Conference9th International Conference on Indoor Air Quality and Climate
Number9
CountryUnited States
CityMonterey, CA
Period30/06/200205/07/2002
Internet address

Cite this

Kaczmarczyk, J., Zeng, Q., Melikov, A. K., & Fanger, P. O. (2002). The effect of a personalized ventilation system on perceived air quality and SBS symptoms. In Proceedings of Indoor Air 2002
Kaczmarczyk, Jan ; Zeng, Q. ; Melikov, Arsen Krikor ; Fanger, Povl Ole. / The effect of a personalized ventilation system on perceived air quality and SBS symptoms. Proceedings of Indoor Air 2002. 2002.
@inproceedings{ceca170294df4686bfffdb83dfd77a89,
title = "The effect of a personalized ventilation system on perceived air quality and SBS symptoms",
abstract = "Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled. Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30{\%}. Results showed that the best condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p",
author = "Jan Kaczmarczyk and Q. Zeng and Melikov, {Arsen Krikor} and Fanger, {Povl Ole}",
year = "2002",
language = "English",
booktitle = "Proceedings of Indoor Air 2002",

}

Kaczmarczyk, J, Zeng, Q, Melikov, AK & Fanger, PO 2002, The effect of a personalized ventilation system on perceived air quality and SBS symptoms. in Proceedings of Indoor Air 2002. 9th International Conference on Indoor Air Quality and Climate, Monterey, CA, United States, 30/06/2002.

The effect of a personalized ventilation system on perceived air quality and SBS symptoms. / Kaczmarczyk, Jan; Zeng, Q.; Melikov, Arsen Krikor; Fanger, Povl Ole.

Proceedings of Indoor Air 2002. 2002.

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

TY - GEN

T1 - The effect of a personalized ventilation system on perceived air quality and SBS symptoms

AU - Kaczmarczyk, Jan

AU - Zeng, Q.

AU - Melikov, Arsen Krikor

AU - Fanger, Povl Ole

PY - 2002

Y1 - 2002

N2 - Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled. Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p

AB - Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled. Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p

M3 - Article in proceedings

BT - Proceedings of Indoor Air 2002

ER -

Kaczmarczyk J, Zeng Q, Melikov AK, Fanger PO. The effect of a personalized ventilation system on perceived air quality and SBS symptoms. In Proceedings of Indoor Air 2002. 2002