TY - JOUR
T1 - SU-8 cantilever chip interconnection
AU - Johansson, Alicia Charlotte
AU - Janting, Jakob
AU - Schultz, Peter
AU - Hoppe, K.
AU - Hansen, I.N.
AU - Boisen, Anja
PY - 2006
Y1 - 2006
N2 - The polymer SU-8 is becoming widely used for all kinds of
micromechanical and microfluidic devices, not only as a photoresist but also
as the constitutional material of the devices. Many of these polymeric
devices need to include a microfluidic system as well as electrical
connection from the electrodes on the SU-8 chip to a printed circuit board.
Here, we present two different methods of electrically connecting an SU-8
chip, which contains a microfluidic network and free-hanging mechanical
parts. The tested electrical interconnection techniques are flip chip bonding
using underfill or flip chip bonding using an anisotropic conductive film
(ACF). These are both widely used in the Si industry and might also be used
for the large scale interconnection of SU-8 chips. The SU-8 chip, to which
the interconnections are made, has a microfluidic channel with integrated
micrometer-sized cantilevers that can be used for label-free biochemical
detection. All the bonding tests are compared with results obtained using
similar Si chips. It is found that it is significantly more complicated to
interconnect SU-8 than Si cantilever chips primarily due to the softness of
SU-8.
AB - The polymer SU-8 is becoming widely used for all kinds of
micromechanical and microfluidic devices, not only as a photoresist but also
as the constitutional material of the devices. Many of these polymeric
devices need to include a microfluidic system as well as electrical
connection from the electrodes on the SU-8 chip to a printed circuit board.
Here, we present two different methods of electrically connecting an SU-8
chip, which contains a microfluidic network and free-hanging mechanical
parts. The tested electrical interconnection techniques are flip chip bonding
using underfill or flip chip bonding using an anisotropic conductive film
(ACF). These are both widely used in the Si industry and might also be used
for the large scale interconnection of SU-8 chips. The SU-8 chip, to which
the interconnections are made, has a microfluidic channel with integrated
micrometer-sized cantilevers that can be used for label-free biochemical
detection. All the bonding tests are compared with results obtained using
similar Si chips. It is found that it is significantly more complicated to
interconnect SU-8 than Si cantilever chips primarily due to the softness of
SU-8.
U2 - 10.1088/0960-1317/16/2/016
DO - 10.1088/0960-1317/16/2/016
M3 - Journal article
VL - 16
SP - 314
EP - 319
JO - Journal of Micromechanics and Microengineering
JF - Journal of Micromechanics and Microengineering
SN - 0960-1317
IS - 2
ER -