Study of LiF:Mg,Cu,P TL detectors for individual monitoring for weakly penetrating radiations

P. Christensen

    Research output: Contribution to journalConference articleResearchpeer-review

    Abstract

    The results are described of a study of three commercially available LiF:Mg,Cu,P TL materials aiming at using this phosphor for individual monitoring for weakly penetrating radiations. Due to the high radiation sensitivity of the material it is suitable for application as thin detectors which are necessary for monitoring weakly penetrating radiations. Furthermore, the good energy response characteristics of the material for exposure to photons makes it also attractive for monitoring strongly penetrating radiations. Results are given on glow curve analyses of the LiF:Mg,Cu,P TL phosphor and data are presented on a number of important dosimetric characteristics of thin detectors prepared from the material, both commercially available detectors and samples prepared in the laboratory. In particular, annealing requirements, and response characteristics of the detectors to beta and photon radiation were studied.
    Original languageEnglish
    JournalRadiation Protection Dosimetry
    Volume47
    Issue number1-4
    Pages (from-to)425-430
    ISSN0144-8420
    Publication statusPublished - 1993
    Event10th International Conference on Solid State Dosimetry - Washington, United States
    Duration: 13 Jul 199217 Jul 1992
    Conference number: 10

    Conference

    Conference10th International Conference on Solid State Dosimetry
    Number10
    Country/TerritoryUnited States
    CityWashington
    Period13/07/199217/07/1992

    Fingerprint

    Dive into the research topics of 'Study of LiF:Mg,Cu,P TL detectors for individual monitoring for weakly penetrating radiations'. Together they form a unique fingerprint.

    Cite this