T1 - Strong low-pass filtering effects on water vapour flux measurements with closed-path eddy correlation systems
AU - Ibrom, Andreas
AU - Dellwik, Ebba
AU - Flyvbjerg, Henrik K.
AU - Jensen, Niels Otto
AU - Pilegaard, Kim
PY - 2007
Y1 - 2007
N2 - Turbulent water vapour fluxes measured with closed-path eddy correlation (EC) systems are unintentionally low-pass filtered by the system in a manner that varies with environmental conditions. Why and how is described here. So is the practical method that systematically corrects long-term flux datasets for this substantial measurement error. In contrast to earlier studies, a large number of spectra and raw data have been used in the analysis to define the low-pass filtering characteristic of the EC system. This revealed that the cut-off frequency of the closed-path EC system for water vapour concentration measurements decreases exponentially with increasing relative humidity. After correction for this unintended filtering, the fluxes are consistent with CO2 and H2O fluxes that were measured with an open-path sensor at the same time. The correction of water vapour flux measurements over a Beech forest in Soro, Zealand, Denmark, amounted on average to 42% of the measured flux, while it was only 4% for the CO2 flux, which was measured with the same EC system. We recommend using the described method to correct water vapour fluxes measured in any closed-path EC system for unintended low-pass filtering effects. Other than for CO2 is the magnitude of the correction for water vapour flux measurements unsatisfactorily high, i.e. the EC system needs to be technically improved. Our results suggest that such high correction can be avoided by keeping relative humidity in the entire gas transport system of the EC system lower than 30%, e.g. by heating intake filters and tubes. (c) 2007 Elsevier B.V. All rights reserved.
AB - Turbulent water vapour fluxes measured with closed-path eddy correlation (EC) systems are unintentionally low-pass filtered by the system in a manner that varies with environmental conditions. Why and how is described here. So is the practical method that systematically corrects long-term flux datasets for this substantial measurement error. In contrast to earlier studies, a large number of spectra and raw data have been used in the analysis to define the low-pass filtering characteristic of the EC system. This revealed that the cut-off frequency of the closed-path EC system for water vapour concentration measurements decreases exponentially with increasing relative humidity. After correction for this unintended filtering, the fluxes are consistent with CO2 and H2O fluxes that were measured with an open-path sensor at the same time. The correction of water vapour flux measurements over a Beech forest in Soro, Zealand, Denmark, amounted on average to 42% of the measured flux, while it was only 4% for the CO2 flux, which was measured with the same EC system. We recommend using the described method to correct water vapour fluxes measured in any closed-path EC system for unintended low-pass filtering effects. Other than for CO2 is the magnitude of the correction for water vapour flux measurements unsatisfactorily high, i.e. the EC system needs to be technically improved. Our results suggest that such high correction can be avoided by keeping relative humidity in the entire gas transport system of the EC system lower than 30%, e.g. by heating intake filters and tubes. (c) 2007 Elsevier B.V. All rights reserved.
KW - Samfund og systemer
U2 - 10.1016/j.agrformet.2007.07.007
DO - 10.1016/j.agrformet.2007.07.007
M3 - Journal article
SN - 0168-1923
VL - 147
SP - 140
EP - 156
JO - Agricultural and Forest Meteorology
JF - Agricultural and Forest Meteorology
IS - 3-4
ER -