Skip to main navigation Skip to search Skip to main content

State-of-the art on the use of performance-based approaches for residential ventilation in 2024

  • Guyot Gaëlle
  • , Valérie Leprince
  • , Poirier Baptiste
  • , Jakub Kolarik
  • Cerema Territoires Et Ville

Research output: Contribution to journal › Journal article › Communication

Abstract

The context of climate change and the need of saving energy has required rethinking the ventilation and the air change rates in buildings, because of their increased impact on thermal losses. Indeed, ventilation plays a
crucial role estimated around 30-50% of the energy delivered to buildings, becoming an even higher part in high-efficient buildings (Liddament and Orme, 1998, AIVC FAQ).

Indoor air quality (IAQ) is another major area of concern in buildings which is influenced by ventilation. Because people spend most of the time in residential buildings (Klepeis et al., 2001) and 60-90% of their life in indoor environments (homes, offices, schools, etc.) (Klepeis et al., 2001; European Commission,2003; Brasche and Bischof, 2005; Zeghnoun et al., 2010; Jantunen et al., 2011), indoor air quality is a major factor affecting public health. Logue et al. (2011b) estimated that the current damage to public health from all sources attributable to IAQ, excluding second-hand smoke (SHS) and radon, was in the range of 4,000–11,000 μDALYs (disability-adjusted life years) per person per year. By way of comparison, this means the damage attributable to indoor air is somewhere between the health effects of road traffic accidents (4,000 μDALYs/p/yr) and heart disease from all causes (11,000 μDALYs/p/yr). According to the World Health Organization (WHO, 2014), 99,000 deaths in Europe and 81,000 in the Americas were attributable to household (indoor) air pollution in 2012.

Thus, by optimizing airflows where and when needs are higher, a smart ventilation system can truly improve IAQ while significantly minimizing energy consumption (Durier et al., 2018; Guyot et al., 2018a). An innovative basis of thought in order to conciliate energy and IAQ in buildings can be proposed for buildings, in the following order: 1. Sufficiency: the best L·s-1 (airflow) is the one we do not need (because the pollutant sources have
been reduced and strictly limited) 2. Aeraulic efficiency: the right L·s-1 is the one renewed at the best time and at the best location (smart ventilation) 3. Air cleaning & filtration: if the two first steps don’t meet IAQ objectives, filtration of air inlet and/or air cleaning are needed.
Original languageEnglish
JournalThe REHVA European HVAC Journal
Pages (from-to)16-19
Publication statusPublished - 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  3. SDG 13 - Climate Action
    SDG 13 Climate Action

Fingerprint

Dive into the research topics of 'State-of-the art on the use of performance-based approaches for residential ventilation in 2024'. Together they form a unique fingerprint.

Cite this