Standards for securing adequate indoor air quality across Europe: setting the scene for health based ventilation guidelines proposed by the HealthVent project

Pawel Wargocki, P. Carrer, E. de Oliveira Fernandes, O. Hanninen, T. Popov

    Research output: Contribution to journalConference abstract in journalResearchpeer-review

    Abstract

    Background: Inadequate IAQ causes a loss of 2 million healthy life years annually in the EU. Europeans spend typically over 85–90% of their time indoors and the main
    factors that affect negatively the characteristics of the air they breathe are outdoor
    air used to ventilate indoor spaces and indoor sources of pollution. Ventilation is
    one of many factors determining IAQ. The aim of DG SANCO funded HealthVent
    project was to assess how ventilation should be defined in terms of achieving
    conditions for securing health.
    Methods: Review of the available literature was made so as to break down the health effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types of diseases and mortality was used in risk analysis. Ventilation rate was defined as volume of fresh air introduced into the space per person (L/sp).
    Results: The data in the reviewed studies on ventilation and health were found inadequate to set the health-based ventilation rates mainly because the studies improperly characterised exposures and because of their inhomogenity. Risk modelling simulations of different strategies resulting in reduction of DALYs suggested that healthbased ventilation requirements should be combined with source control strategies and if necessary cleaning of outdoor air in order to be efficient. As a consequence HealthVent proposed that source control is
    a key strategy for IAQ and that ventilation should be an ultimate measure. HealthVent defined the minimum reference ventilation rate to reduce risk of health to be set at 4 L/s per person. This rate is only to handle human bioeffluents and is determined mainly considering the metabolic CO2 production.
    It is only applicable if all other pollutants meet WHO guidelines for ambient and indoor air quality. If they do not meet these guidelines after applying source
    control and when air used for ventilation is clean health-based ventilation rate should be a multiple of the minimum rate.
    Conclusions: Optimal strategy for ensuring adequate IAQ to ensure health conditions must include cleaning of ambient air (if necessary) and source control; only then health-based ventilation rate can be defined. Such approach is expected to half the BOD caused by indoor exposures.
    Original languageEnglish
    Article number367
    JournalAllergy: European Journal of Allergy and Clinical Immunology
    Volume68
    Issue numberSupplement s97
    Pages (from-to)170
    ISSN0105-4538
    Publication statusPublished - 2013
    EventEuropean Academy of Allergy and Clinical Immunology & World Allergy Organization World Allergy & Asthma Congress - Milan, Italy
    Duration: 22 Jun 201326 Jun 2013
    http://www.eaaci-wao2013.com/general+information/welcome/5775/Page.aspx

    Conference

    ConferenceEuropean Academy of Allergy and Clinical Immunology & World Allergy Organization World Allergy & Asthma Congress
    Country/TerritoryItaly
    CityMilan
    Period22/06/201326/06/2013
    Internet address

    Fingerprint

    Dive into the research topics of 'Standards for securing adequate indoor air quality across Europe: setting the scene for health based ventilation guidelines proposed by the HealthVent project'. Together they form a unique fingerprint.

    Cite this