    The report describes a number of new techniques for processing data from the Danish Airborne Gamma-Ray Spectrometry systems. The techniques include the standard windows technique and the newly developed Noise Adjusted Singular Value Decomposition technique. The methods used for producing maps prom the results are also described .
    Original languageEnglish
    Number of pages34
    Publication statusPublished - 1998

    Cite this

    Bargholz, Kim ; Korsbech, Uffe C C ; Hovgaard, Jens. / Standard methods for processing data from the Danish Airborne Gamma-ray Spectrometry system. 1998. 34 p.
    @book{7b8b23e378144ad788c734dd58a14370,
    title = "Standard methods for processing data from the Danish Airborne Gamma-ray Spectrometry system",
    abstract = "The report describes a number of new techniques for processing data from the Danish Airborne Gamma-Ray Spectrometry systems. The techniques include the standard windows technique and the newly developed Noise Adjusted Singular Value Decomposition technique. The methods used for producing maps prom the results are also described .",
    author = "Kim Bargholz and Korsbech, {Uffe C C} and Jens Hovgaard",
    year = "1998",
    language = "English",

    }

    Standard methods for processing data from the Danish Airborne Gamma-ray Spectrometry system. / Bargholz, Kim; Korsbech, Uffe C C; Hovgaard, Jens.

    1998. 34 p.

    Research output: Book/ReportReportResearchpeer-review

    TY - RPRT

    T1 - Standard methods for processing data from the Danish Airborne Gamma-ray Spectrometry system

    AU - Bargholz, Kim

    AU - Korsbech, Uffe C C

    AU - Hovgaard, Jens

    PY - 1998

    Y1 - 1998

    N2 - The report describes a number of new techniques for processing data from the Danish Airborne Gamma-Ray Spectrometry systems. The techniques include the standard windows technique and the newly developed Noise Adjusted Singular Value Decomposition technique. The methods used for producing maps prom the results are also described .

    AB - The report describes a number of new techniques for processing data from the Danish Airborne Gamma-Ray Spectrometry systems. The techniques include the standard windows technique and the newly developed Noise Adjusted Singular Value Decomposition technique. The methods used for producing maps prom the results are also described .

    M3 - Report

    BT - Standard methods for processing data from the Danish Airborne Gamma-ray Spectrometry system

    ER -