Solar combi system based on a mantle tank

Eshagh Yazdanshenas (Invited author), Simon Furbo (Invited author)

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Abstract

A solar combisystem based on a mantle tank is investigated numerically and experimentally. Three different houses with four different radiator systems are considered for the simulations. The needed temperature for the auxiliary heater is determined for different houses and radiator systems. The thermal performance of the solar combisystem is compared to the thermal performance of a solar domestic hot water system based on a mantle tank. In the experimental study, tank temperatures and the heat transfer coefficient for the top mantle for a discharge test is determined. The investigations showed that the investigated concept is promising for low energy buildings.
Original languageEnglish
Title of host publicationProceedings of ISES Solar World Congress 2007
Volume4
Publication date2007
Pages2716-2720
Publication statusPublished - 2007
EventISES Solar World Congress 2007 - Beijing, China
Duration: 18 Sep 200721 Sep 2007
https://www.ises.org/ISES.nsf/5c990687ba31ff01c12568b3004ef917/199bb81ccb4fa044c1257448002e2f2b?OpenDocument

Conference

ConferenceISES Solar World Congress 2007
CountryChina
CityBeijing
Period18/09/200721/09/2007