Abstract
A solar combisystem based on a mantle tank is investigated numerically and experimentally. Three different houses with four different radiator systems are considered for the simulations. The needed temperature for the auxiliary heater is determined for different houses and radiator systems. The thermal performance of the solar combisystem is compared to the thermal performance of a solar domestic hot water system based on a mantle tank. In the experimental study, tank temperatures and the heat transfer coefficient for the top mantle for a discharge test is determined. The investigations showed that the investigated concept is promising for low energy buildings.
Original language | English |
---|---|
Title of host publication | Proceedings of ISES Solar World Congress 2007 |
Volume | 4 |
Publication date | 2007 |
Pages | 2716-2720 |
Publication status | Published - 2007 |
Event | ISES Solar World Congress 2007: The technical code and handbook for solar heating combisystems - Beijing, China Duration: 18 Sept 2007 → 21 Sept 2007 https://www.ises.org/ISES.nsf/5c990687ba31ff01c12568b3004ef917/199bb81ccb4fa044c1257448002e2f2b?OpenDocument |
Conference
Conference | ISES Solar World Congress 2007 |
---|---|
Country/Territory | China |
City | Beijing |
Period | 18/09/2007 → 21/09/2007 |
Internet address |