Abstract
This paper presents a PV panel simulation model using the single-diode four-parameter model based on data sheet values. The model was implemented first in MATLAB/Simulink, and the results have been compared with the data sheet values and characteristics of the PV panels in standard test conditions. Moreover to point out the strong dependency on ambient conditions and its influence on array operation and to validate simulation results with measured data a complex model has also been developed. A PV inverter model, using the same equations and parameters as in MATLAB/Simulink has also been developed and implemented in PowerFactory to study load flow, steady-state voltage stability and dynamic behavior of a distributed power system.
Original language | English |
---|---|
Title of host publication | Proceedings of the 8th International Symposium on Applied Computational Intelligence and Informatics-SACI 2012 |
Number of pages | 6 |
Publication date | 2012 |
Pages | 257-261 |
ISBN (Print) | 1-4244-1234-X |
Publication status | Published - 2012 |
Event | 8th International Symposium on Applied Computational Intelligence and Informatics-SACI 2012 - Timisoara, Romania Duration: 24 May 2012 → 26 May 2012 |
Conference
Conference | 8th International Symposium on Applied Computational Intelligence and Informatics-SACI 2012 |
---|---|
Country/Territory | Romania |
City | Timisoara |
Period | 24/05/2012 → 26/05/2012 |