Abstract
Internal insulation is often the only measure to reduce heat loss for facades that are worth preservation, both from a sustainable and architectural point of view. However, insulation from inside may make the original wall vulnerable for mois-ture related problems. Recent years, quite a lot of research on moisture safe inter-nal insulation of solid brick masonry walls has been conducted.
This study takes up the challenge of transforming the experiences from solid brick masonry walls to facades of modern/industrial era up to 1980’s. Brick masonry is still often on the exterior side but combined with concrete or light weight concrete on the inte-rior side with or without a cavity. Hardly any research on this topic has been conducted and therefore this paper introduces some first investigations of the hy-grothermal performance of retrofitting above types of facades from inside.
The study is conducted as a simulation study, where a number of relevant construc-tions and insulation systems are analysed. Solid brick masonry is used as refer-ence. The results indicate that internal insulation has a good potential for most masonry facades of modern/industrial era. However, insulating solid concrete fa-cades from inside is only possible under certain circumstances.
This study takes up the challenge of transforming the experiences from solid brick masonry walls to facades of modern/industrial era up to 1980’s. Brick masonry is still often on the exterior side but combined with concrete or light weight concrete on the inte-rior side with or without a cavity. Hardly any research on this topic has been conducted and therefore this paper introduces some first investigations of the hy-grothermal performance of retrofitting above types of facades from inside.
The study is conducted as a simulation study, where a number of relevant construc-tions and insulation systems are analysed. Solid brick masonry is used as refer-ence. The results indicate that internal insulation has a good potential for most masonry facades of modern/industrial era. However, insulating solid concrete fa-cades from inside is only possible under certain circumstances.
| Original language | English |
|---|---|
| Title of host publication | Proceedings of IBPC2024 : 9th International Building Physics Conference |
| Editors | U. Berardi |
| Publisher | International Association of Building Physics |
| Publication date | 2025 |
| Pages | 495–501 |
| ISBN (Print) | 978-981-97-8304-5 |
| ISBN (Electronic) | 978-981-97-8305-2 |
| DOIs | |
| Publication status | Published - 2025 |
| Event | 9th International Buildings Physics Conference - Toronto Metropolitan University, Toronto, Canada Duration: 25 Jul 2024 → 27 Jul 2024 |
Conference
| Conference | 9th International Buildings Physics Conference |
|---|---|
| Location | Toronto Metropolitan University |
| Country/Territory | Canada |
| City | Toronto |
| Period | 25/07/2024 → 27/07/2024 |
| Series | Lecture Notes in Civil Engineering |
|---|---|
| Volume | 552 |
| ISSN | 2366-2557 |
Fingerprint
Dive into the research topics of 'Retrofitting facades of modern/industrial era from inside: Hygrothermal performance'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver