Relationships in Indoor/Outdoor Air Pollution

Jørn Roed

    Research output: Book/ReportReport

    23 Downloads (Pure)

    Abstract

    Beryllium-7 and sulphurhexaflourid has been used as tracers in measurements designed to enable an estimate of the ratio of the outdoor to indoor time-integrated concentration for aerosols and non-reactive gasses of outdoor origin
    with a special reference to the reduction in inhalation dose that can be achieved by staying indoors during a pollution episode, especially a reactor accident. The effect of operating a vacuum cleaner during the pollution episode and airing shortly after is also investigated. Earlier relevant literature is reviewed and shows good agreement with the results in this study. Protection factor from 1-12 has been found.
    Original languageEnglish
    Place of PublicationRoskilde, Denmark
    PublisherRisø National Laboratory
    Number of pages41
    ISBN (Print)87-550-1072-5
    Publication statusPublished - 1985
    SeriesRisoe-M
    Number2476
    ISSN0418-6435

    Keywords

    • Risø-M-2476

    Cite this

    Roed, J. (1985). Relationships in Indoor/Outdoor Air Pollution. Risø National Laboratory. Risoe-M, No. 2476