Abstract
Hearing threshold determinations have been performed with EARTONE 3A insert earphones and compared with threshold measurements performed with TDH 39 supra-aural earphones. 22 normal hearing subjects participated. Results are given as SPL values measured in an acoustic coupler (IEC 126) and an occluded-ear simulator (IEC 711)
Original language | English |
---|---|
Journal | Scandinavian Audiology |
Volume | 20 |
Issue number | 3 |
Pages (from-to) | 205-207 |
ISSN | 0105-0397 |
DOIs | |