Real Time Deconvolution of In-Vivo Ultrasound Images

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    522 Downloads (Orbit)

    Abstract

    The axial resolution in medical ultrasound is directly linked to the emitted ultrasound frequency, which, due to tissue attenuation, is selected based on the depth of scanning. The resolution is etermined by the transducers impulse response, which limits the attainable resolution to be between one and two wavelengths. This can be improved by deconvolution, which increase the bandwidth and equalizes the phase to increase resolution under the constraint of the electronic noise in the received signal. A fixed interval Kalman filter based deconvolution routine written in C is employed. It uses a state based model for the ultrasound pulse and can include a depth varying pulse and spatially varying signal-to-noise ration. An autoregressive moving average (ARMA) model of orders 8 and 9 is used for the pulse, and the ARMA parameters are determined as a function of depth using a minimum variance algorithm using averaging over several RF lines. In vivo data from a 3 MHz mechanically rotating probe is used and the received signal is sampled at 20 MHz and 12 bits. In-vivo data acquired from a 16th week old fetus is used along with a scan from the liver and right kidney of a 27 years old male. The axial resolution has been determined from the in-vivo liver image using the auto-covariance function. From the envelope of the estimated pulse the axial resolution at Full-Width-Half-Max is 0.581 mm corresponding to 1.13 l at 3 MHz. The algorithm increases the resolution to 0.116 mm or 0.227 l corresponding to a factor of 5.1. The basic pulse can be estimated in roughly 0.176 seconds on a single CPU core on an Intel i5 CPU running at 1.8 GHz. An in-vivo image consisting of 100 lines of 1600 samples can be processed in roughly 0.1 seconds making it possible to perform real-time deconvolution on ultrasound data by using dual or quad core CPUs for frame-rates of 20-40 Hz.
    Original languageEnglish
    Title of host publicationProceedings of IEEE International Ultrasonics Symposium
    PublisherIEEE
    Publication date2013
    Pages29-32
    ISBN (Print)9781467356862
    DOIs
    Publication statusPublished - 2013
    Event2013 IEEE International Ultrasonics Symposium - Prague Convention Center , Prague, Czech Republic
    Duration: 21 Jul 201325 Jul 2013
    http://ewh.ieee.org/conf/uffc/2013/

    Conference

    Conference2013 IEEE International Ultrasonics Symposium
    LocationPrague Convention Center
    Country/TerritoryCzech Republic
    CityPrague
    Period21/07/201325/07/2013
    Internet address

    Keywords

    • Fields, Waves and Electromagnetics
    • Deconvolution
    • Estimation
    • Image resolution
    • Signal resolution
    • Signal to noise ratio
    • Ultrasonic imaging

    Fingerprint

    Dive into the research topics of 'Real Time Deconvolution of In-Vivo Ultrasound Images'. Together they form a unique fingerprint.

    Cite this