Abstract
Paper accepted for presentation to the Third International Conference on Composite Materials in Paris, France, 26 - 29 August, 1980.
The usefulnes of the radiographic technique in the examination of Spinrock fibres reinforced cement plates was investigated with soft X-rays.
A preliminary investigation has shown that soft X-rays are most suitable for radiography of cement plates, and therefore a 50 kV X-ray machine with a 0.5 mm focus and beryllium window X-ray tube was used throughout the investigation. X-ray films of different speed and graininess were used, and it was proved that a relatively fast Kodak Industrex D film can produce radiographs of
adequate quality. An Agfa-Gevaert Structurix IC paper can also be used.
Radiographs of cement plates, taken both on X-ray film and paper were scanned using a transmission or reflection densitometer. Optical density readings from the densitometer were fed into a paper chart recorder.
The results of the radiographic test were transferred to a quantitative measure by densitometer scanning from which the relative standard deviations in the optical densities were used. These measures show a significant correlation with the flexural strengths, measured on the same specimens.
We therefore conclude that the material distribution can be measured oy X-ray radiography, and that this distribution is a very important parameter for the evaluation of the quality of cement plates reinforced with discontinuous mineral fibres.
The usefulnes of the radiographic technique in the examination of Spinrock fibres reinforced cement plates was investigated with soft X-rays.
A preliminary investigation has shown that soft X-rays are most suitable for radiography of cement plates, and therefore a 50 kV X-ray machine with a 0.5 mm focus and beryllium window X-ray tube was used throughout the investigation. X-ray films of different speed and graininess were used, and it was proved that a relatively fast Kodak Industrex D film can produce radiographs of
adequate quality. An Agfa-Gevaert Structurix IC paper can also be used.
Radiographs of cement plates, taken both on X-ray film and paper were scanned using a transmission or reflection densitometer. Optical density readings from the densitometer were fed into a paper chart recorder.
The results of the radiographic test were transferred to a quantitative measure by densitometer scanning from which the relative standard deviations in the optical densities were used. These measures show a significant correlation with the flexural strengths, measured on the same specimens.
We therefore conclude that the material distribution can be measured oy X-ray radiography, and that this distribution is a very important parameter for the evaluation of the quality of cement plates reinforced with discontinuous mineral fibres.
| Original language | English |
|---|
| Place of Publication | Roskilde, Denmark |
|---|---|
| Publisher | Risø National Laboratory |
| Number of pages | 21 |
| ISBN (Print) | 87-550-0661-2 |
| Publication status | Published - 1980 |
| Series | Risø-M |
|---|---|
| Number | 2222 |
| ISSN | 0418-6435 |
Keywords
- Risø-M-2222
- Cements
- Composite materials
- Densitometers
- Fibers
- Image scanners
- Industrial radiography
- Paper
- Photographic films
- Plates
- Soft x radiation
- X-ray radiography
Fingerprint
Dive into the research topics of 'Radiographic control of mineral fibre-reinforced cement plates'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver