Skip to main navigation Skip to search Skip to main content

Radiographic control of mineral fibre-reinforced cement plates

  • J.C. Domanus
  • , L. Møller-Jensen
    • Rockwool International

    Research output: Book/Report › Report › Research

    352 Downloads (Orbit)

    Abstract

    Paper accepted for presentation to the Third International Conference on Composite Materials in Paris, France, 26 - 29 August, 1980.

    The usefulnes of the radiographic technique in the examination of Spinrock fibres reinforced cement plates was investigated with soft X-rays.

    A preliminary investigation has shown that soft X-rays are most suitable for radiography of cement plates, and therefore a 50 kV X-ray machine with a 0.5 mm focus and beryllium window X-ray tube was used throughout the investigation. X-ray films of different speed and graininess were used, and it was proved that a relatively fast Kodak Industrex D film can produce radiographs of
    adequate quality. An Agfa-Gevaert Structurix IC paper can also be used.

    Radiographs of cement plates, taken both on X-ray film and paper were scanned using a transmission or reflection densitometer. Optical density readings from the densitometer were fed into a paper chart recorder.

    The results of the radiographic test were transferred to a quantitative measure by densitometer scanning from which the relative standard deviations in the optical densities were used. These measures show a significant correlation with the flexural strengths, measured on the same specimens.

    We therefore conclude that the material distribution can be measured oy X-ray radiography, and that this distribution is a very important parameter for the evaluation of the quality of cement plates reinforced with discontinuous mineral fibres.
    Original languageEnglish
    Place of PublicationRoskilde, Denmark
    PublisherRisø National Laboratory
    Number of pages21
    ISBN (Print)87-550-0661-2
    Publication statusPublished - 1980
    SeriesRisø-M
    Number2222
    ISSN0418-6435

    Keywords

    • Risø-M-2222
    • Cements
    • Composite materials
    • Densitometers
    • Fibers
    • Image scanners
    • Industrial radiography
    • Paper
    • Photographic films
    • Plates
    • Soft x radiation
    • X-ray radiography