Skip to main navigation Skip to search Skip to main content

Preliminary comparison between real-time in-vivo spectral and transverse oscillation velocity estimates

  • Mads Møller Pedersen
  • , Michael Johannes Pihl
  • , Per Haugaard
  • , Jens Munk Hansen
  • , Kristoffer Lindskov Hansen
  • , Michael Bachmann Nielsen
  • , Jørgen Arendt Jensen
    • BK Medical ApS
    • Copenhagen University Hospital Herlev and Gentofte

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    506 Downloads (Orbit)

    Abstract

    Spectral velocity estimation is considered the gold standard in medical ultrasound. Peak systole (PS), end diastole (ED), and resistive index (RI) are used clinically. Angle correction is performed using a flow angle set manually. With Transverse Oscillation (TO) velocity estimates the flow angle, peak systole (PSTO), end diastole (EDTO), and resistive index (RITO) are estimated. This study investigates if these clinical parameters are estimated equally good using spectral and TO data. The right common carotid arteries of three healthy volunteers were scanned longitudinally. Average TO flow angles and std were calculated { 52±18 ; 55±23 ; 60±16 }°. Spectral angles { 52 ; 56 ; 52 }° were obtained from the B-mode images. Obtained values are: PSTO { 76±15 ; 89±28 ; 77±7 } cm/s, spectral PS { 77 ; 110 ; 76 } cm/s, EDTO { 10±3 ; 14±8 ; 15±3 } cm/s, spectral ED { 18 ; 13 ; 20 } cm/s, RITO { 0.87±0.05 ; 0.79±0.21 ; 0.79±0.06 }, and spectral RI { 0.77 ; 0.88 ; 0.73 }. Vector angles are within ±two std of the spectral angle. TO velocity estimates are within ±three std of the spectral estimates. RITO are within ±two std of the spectral estimates. Preliminary data indicates that the TO and spectral velocity estimates are equally good. With TO there is no manual angle setting and no flow angle limitation. TO velocity estimation can also automatically handle situations where the angle varies over the cardiac cycle. More detailed temporal and spatial vector estimates with diagnostic potential are available with the TO velocity estimation.
    Original languageEnglish
    Title of host publicationProceedings of SPIE
    EditorsJan D'hooge, Marvin M. Doyley
    Volume7968
    PublisherSPIE - International Society for Optical Engineering
    Publication date2011
    ISBN (Print)9780819485106
    DOIs
    Publication statusPublished - 2011
    EventSPIE Medical Imaging 2011 - Disney's Coronado Springs Resort, Lake Buena Vista, United States
    Duration: 12 Feb 201117 Feb 2011

    Conference

    ConferenceSPIE Medical Imaging 2011
    LocationDisney's Coronado Springs Resort
    Country/TerritoryUnited States
    CityLake Buena Vista
    Period12/02/201117/02/2011

    Bibliographical note

    Article Number: 79680K

    Keywords

    • Vector flow
    • In vivo
    • Transverse oscillation
    • Blood velocity
    • Ultrasound imaging
    • Spectral estimation

    Fingerprint

    Dive into the research topics of 'Preliminary comparison between real-time in-vivo spectral and transverse oscillation velocity estimates'. Together they form a unique fingerprint.

    Cite this