Planck 2013 results X. Energetic particle effects: characterization, removal, and simulation

Planck Collaboration,, P. A. R. Ade, N. Aghanim, C. Armitage-Caplan, M. Arnaud, M. Ashdown, F. Atrio-Barandela, J. Aumont, C. Baccigalupi, A. J. Banday, R. B. Barreiro, E. Battaner, K. Benabed, A. Benoît, A. Benoit-Lévy, J. -P. Bernard, M. Bersanelli, P. Bielewicz, J. Bobin, Jacob BockJ. R. Bond, J. Borrill, F. R. Bouchet, M. Bridges, M. Bucher, C. Burigana, J. -F. Cardoso, A. Catalano, A. Challinor, A. Chamballu, Lung-Yih Chiang, H. C. Chiang, P. R. Christensen, S. Church, D. L. Clements, S. Colombi, L. P. L. Colombo, F. Couchot, A. Coulais, B. P. Crill, A. Curto, F. Cuttaia, L. Danese, R. D. Davies, P. de Bernardis, A. de Rosa, G. de Zotti, J. Delabrouille, J. -M. Delouis, F. -X. Désert, J. M. Diego, H. Dole, S. Donzelli, O. Doré, M. Douspis, X. Dupac, G. Efstathiou, T. A. Enßlin, H. K. Eriksen, F. Finelli, O. Forni, M. Frailis, E. Franceschi, S. Galeotta, K. Ganga, M. Giard, D. Girard, Y. Giraud-Héraud, J. González-Nuevo, K. M. Górski, S. Gratton, A. Gregorio, A. Gruppuso, F. K. Hansen, D. Hanson, D. Harrison, S. Henrot-Versillé, C. Hernández-Monteagudo, D. Herranz, Steen Hildebrandt, E. Hivon, M. Hobson, W. A. Holmes, Allan Hornstrup, W. Hovest, K. M. Huffenberger, T. R. Jaffe, A. H. Jaffe, W. C. Jones, M. Juvela, E. Keihänen, R. Keskitalo, T. S. Kisner, R. Kneissl, J. Knoche, L. Knox, M. Kunz, H. Kurki-Suonio, G. Lagache, J. -M. Lamarre, A. Lasenby, R. J. Laureijs, C. R. Lawrence, R. Leonardi, C. Leroy, J. Lesgourgues, M. Liguori, P. B. Lilje, Michael Linden-Vørnle, M. López-Caniego, P. M. Lubin, J. F. Macías-Pérez, N. Mandolesi, M. Maris, D. J. Marshall, P. G. Martin, E. Martínez-González, S. Masi, S. Matarrese, F. Matthai, P. Mazzotta, P. McGehee, A. Melchiorri, L. Mendes, A. Mennella, M. Migliaccio, A. Miniussi, S. Mitra, M. -A. Miville-Deschênes, A. Moneti, L. Montier, G. Morgante, D. Mortlock, S. Mottet, D. Munshi, Jonathan Murphy, P. Naselsky, F. Nati, P. Natoli, C. B. Netterfield, Hans Ulrik Nørgaard-Nielsen, F. Noviello, D. Novikov, Igor Dmitrievich Novikov, S. Osborne, Carol Anne Oxborrow, F. Paci, L. Pagano, F. Pajot, D. Paoletti, F. Pasian, G. Patanchon, O. Perdereau, L. Perotto, F. Perrotta, F. Piacentini, M. Piat, E. Pierpaoli, D. Pietrobon, S. Plaszczynski, E. Pointecouteau, G. Polenta, N. Ponthieu, L. Popa, T. Poutanen, G. W. Pratt, G. Prézeau, S. Prunet, J. -L. Puget, J. P. Rachen, B. Racine, M. Reinecke, M. Remazeilles, C. Renault, S. Ricciardi, T. Riller, I. Ristorcelli, G. Rocha, C. Rosset, G. Roudier, B. Rusholme, L. Sanselme, D. Santos, A. Sauvé, G. Savini, E. P. S. Shellard, L. D. Spencer, J. -L. Starck, V. Stolyarov, R. Stompor, R. Sudiwala, F. Sureau, D. Sutton, A. -S. Suur-Uski, J. -F. Sygnet, J. A. Tauber, D. Tavagnacco, L. Terenzi, L. Toffolatti, M. Tomasi, M. Tristram, M. Tucci, G. Umana, L. Valenziano, J. Valiviita, B. Van Tent, P. Vielva, Frank Villa, N. Vittorio, L. A. Wade, B. D. Wandelt, D. Yvon, A. Zacchei, A. Zonca

    Research output: Contribution to journalJournal articleResearchpeer-review

    159 Downloads (Orbit)

    Abstract

    This paper presents the detection, interpretation and removal of the signal resulting from interactions of high energy particles with the Planck High Frequency Instrument (HFI). These interactions fall into two categories, heating the 0.1 K bolometer plate and glitches in each detector time stream. Glitch shapes are not simple single pole exponential decays and fall into a three families. The glitch shape for each family has been characterized empirically in flight data and removed from the detector time streams. The spectrum of the count rate/unit energy is computed for each family and a correspondence to where on the detector the particle hit is made. Most of the detected glitches are from galactic protons incident on the Si die frame supporting the micromachined bolometric detectors. At HFI, the particle flux is ~ 5 per square cm and per second and is dominated by protons incident on the spacecraft with an energy >39 MeV, leading to a rate of typically one event per second and per detector. Different categories of glitches have different signature in timestreams. Two of the glitch types have a low amplitude component that decays over nearly 1 second. This component produces an excess noise if not properly removed from the time ordered data. We have used a glitch detection and subtraction method based on the joint fit of population templates. The application of this novel glitch removal method removes excess noise from glitches. Using realistic simulations, we find this method does not introduce signal bias.
    Original languageEnglish
    JournalArXiv Astrophysics e-prints
    Number of pages23
    Publication statusPublished - 2013

    Fingerprint

    Dive into the research topics of 'Planck 2013 results X. Energetic particle effects: characterization, removal, and simulation'. Together they form a unique fingerprint.

    Cite this