Physics-Informed Tensor Velocity Reconstruction from 2D Velocity Estimates using Row-Column Probes

  • Lasse Thurmann Jørgensen
  • , Rikke Bannebjerg Baarts
  • , Alexander Cuculiza Henriksen
  • , Michael Bachmann Nielsen
  • , Jørgen Arendt Jensen
  • University of Copenhagen

Research output: Contribution to journal › Journal article › Research › peer-review

40 Downloads (Orbit)

Abstract

A method is presented for estimating three-dimensional (3D) velocity fields over space-time (tensor velocity fields), by combining two-dimensional (2D) velocity estimates acquired in multiple imaging planes with the continuity equation. The proposed tensor velocity estimator accurately reconstructs flow within the aliasing limit and mitigates motion-related artifacts observed in synthetic aperture and plane wave imaging techniques, which typically reduce estimation accuracy at higher velocities. The estimator is demonstrated using both a short imaging sequence, which estimates the tensor velocity field in a thin volume (effectively a 2D slice), and a longer sequence for reconstructing flow over a larger volume. A singular value decomposition (SVD) procedure for phase-shift noise reduction is also proposed. In addition to improving the estimation precision, the method significantly reduces the required storage space and input size for the reconstruction algorithm: from approximately 20 GB to 110 MB in one measurement. Furthermore, the procedure enables quick analysis of the SVD components contributions to the flow. Flow-rig measurements of parabolic flow was acquired at various combinations of beam-to-flow angles (60°, 75°, and 90°) and flow-rotation angles (50° and 90°), with peak velocities ranging from approximately 10% to 95% of the velocity aliasing limit. The average bias for the velocity magnitude was found to be −0.71 ± 2.96%, and the standard deviation was 0.57 ± 0.19%. From Field II simulations of pulsatile carotid artery flows, the estimator reconstructs the velocity magnitude over a 3.5 s period with a normalized root-mean-square error of 3.57%. In measurements of flow in a carotid artery phantom, the average velocity magnitude pulse profiles of the mean and peak velocities were estimated with standard deviations of 0.75% and 2.63%. Similarly, in vivo measurements of the carotid artery bifurcation yielded mean and peak velocity magnitude profiles with estimated standard deviations of 1.06% and 2.51%. These results demonstrate that the proposed estimator can accurately and precisely reconstruct tensor velocity fields in clinically relevant and high-velocity flow scenarios.
Original languageEnglish
Article number11625834
JournalIEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Volume73
Issue number8
Number of pages16
ISSN0885-3010
DOIs
Publication statusPublished - 2026

Keywords

  • Fluid flow
  • Vectors
  • Planing
  • Estimation
  • Arrays
  • Measurement
  • Sequential analysis
  • Sequences
  • Ranking (statistics)
  • Ultrasonic imaging

Fingerprint

Dive into the research topics of 'Physics-Informed Tensor Velocity Reconstruction from 2D Velocity Estimates using Row-Column Probes'. Together they form a unique fingerprint.

Cite this