Perfusion vector - a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients

David Minarik, Martin Senneby, Per Wollmer, Alva Mansten, Karl Sjöstrand, Lars Edenbrandt, Elin Trägårdh

    Research output: Contribution to journalJournal articleResearchpeer-review

    243 Downloads (Pure)

    Abstract

    Background The interpretation of myocardial perfusion scintigraphy (MPS) largely relies on visual assessment by the physician of the localization and extent of a perfusion defect. The aim of this study was to introduce the concept of the perfusion vector as a new objective quantitative method for further assisting the visual interpretation and to test the concept using simulated MPS images as well as patients. Methods The perfusion vector is based on calculating the difference between the anatomical centroid and the perfusion center of gravity of the left ventricle. Simulated MPS images were obtained using the SIMIND Monte Carlo program together with XCAT phantom. Four different-sized anterior and four lateral defects were simulated, and perfusion vector components x-, y-, and z-axes were calculated. For the patient study, 40 normal and 80 abnormal studies were included. Perfusion vectors were compared between normal and abnormal (apical, inferior, anterior, and lateral ischemia or infarction) studies and also correlated to the defect size. Results For simulated anterior defects, the stress perfusion vector component on the y-axis (anterior-inferior direction) increased in proportion to the defect size. For the simulated lateral defects, the stress perfusion vector component on the x-axis (septal-lateral direction) decreased in proportion to the defect size. When comparing normal and abnormal patients, there was a statistically significant difference for the stress perfusion vector on the x-axis for apical and lateral defects; on the y-axis for apical, inferior, and lateral defects; and on the z-axis (basal-apical direction) for apical, anterior, and lateral defects. A significant difference was shown for the difference vector magnitude (stress/rest) between normal and ischemic patients (p = 0.001) but not for patients with infarction. The correlation between the defect size and stress vector magnitude was also found to be significant (p < 0.001). Conclusions The concept of the perfusion vector introduced in this study is shown to have potential in assisting the visual interpretation in MPS studies. Further studies are needed to validate the concept in patients.
    Original languageEnglish
    Article number42
    JournalEJNMMI Research
    Volume5
    Issue number1
    Pages (from-to)1-8
    ISSN2191-219X
    Publication statusPublished - 2015

    Keywords

    • SPECT
    • Ischemic heart disease
    • Quantification
    • Automated method

    Fingerprint

    Dive into the research topics of 'Perfusion vector - a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients'. Together they form a unique fingerprint.

    Cite this