    Abstract

    This paper evaluates the daylighting performance of a prototype external dynamic shading and daylight-redirecting system, and the main focus is on the performance simulation. The demonstration project was carried out on a building with an open-plan office. Part of the original façade was replaced with the prototype façade. This layout allowed the use of the same orientation and surroundings for both façades. The working plane illuminance was measured over several months and the measurements were accompanied with annual daylight simulations. The prototype system improved the daylighting conditions compared to the original system. The visual comfort was evaluated by glare analysis and the redirected daylight did not cause an additional discomfort glare. The higher utilization of daylight can save 20% of the lighting energy. The thermal insulation of the fenestration was maintained, with slightly increased solar gains, but without producing an excessive overheating. © 2013 Elsevier B.V. All rights reserved.
    Original languageEnglish
    JournalEnergy and Buildings
    Volume64
    Pages (from-to)309-316
    ISSN0378-7788
    DOIs
    Publication statusPublished - 2013

    Keywords

    • Shading system
    • Daylight
    • Redirecting light
    • Illuminance measurements
    • Indoor climate
    • Visual comfort