Abstract
District heating systems (DHS) are driven by the heat demands of their consumers, with higher demands giving a higher load on the heat production. While heat demands are human-dependent, they contain diurnal behaviors and weather dependencies. The diurnal behaviors contain periods with high demands causing peak loads on the heat production, which is operationally costly. This is especially true for heat pumps, a solution for DHS to include green energy, as the cost depends directly on the needed temperature. This paper presents a formulation of adaptive model predictive control (MPC) for inducing peak shaving on the production load to handle the peak load problem by using the DHS distribution network as a heat storage. It also presents a simulator model to describe the DHS. The MPC was applied to data from a case study of the DHS in Brønderslev, Denmark, showing a peak reduction of around (Formula presented.).
| Original language | English |
|---|---|
| Article number | 8555 |
| Journal | Energies |
| Volume | 15 |
| Issue number | 22 |
| Number of pages | 15 |
| ISSN | 1996-1073 |
| DOIs | |
| Publication status | Published - Nov 2022 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Adaptive control
- Data-driven modeling
- District heating
- MPC
Fingerprint
Dive into the research topics of 'Peak Shaving in District Heating Utilizing Adaptive Predictive Control'. Together they form a unique fingerprint.Cite this