Parameter sensitivity study of a Field II multilayer transducer model on a convex transducer

David Bæk, Jørgen Arendt Jensen, Morten Willatzen

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    663 Downloads (Pure)

    Abstract

    A multilayer transducer model for predicting a transducer impulse response has in earlier works been developed and combined with the Field II software. This development was tested on current, voltage, and intensity measurements on piezoceramics discs (Bæk et al. IUS 2008) and a convex 128 element ultrasound imaging transducer (Bæk et al. ICU 2009). The model benefits from its 1D simplicity and hasshown to give an amplitude error around 1.7‐2 dB. However, any prediction of amplitude, phase, and attenuation of pulses relies on the accuracy of manufacturer supplied material characteristics, which may be inaccurate estimates. The previous test cases have assumed the simulation parameters to be exact as received from the manufacturer. In this paper the influence of a deviation in the accuracy of the different parameters is studied by comparing simulation and measurement. The long term objective is a quantitative calibrated model for a complete ultrasound system. This includes a sensitivity study aspresented here.Statement of Contribution/MethodsThe study alters 35 different model parameters which describe a 128 element convex transducer from BK Medical Aps. The changes are within ±20 % of the values supplied by the manufacturer, which are considered the zero reference (ZR). Simulations of a system consisting of a transmit unit, a five material layer transducer, and the FIELD II predicted pressure are performed by altering in turn the value of a single parameter in steps of 2 %. The remaining simulation parameters are held fixed at the ZR. The influence of the parameter change is determined by calculating the pressure and the intensity at adistance of 112 mm on an element’s center axis and comparing it with hydrophone measurements. These are performed with a water bath hydrophone setup using an Agilent MSO6014A oscilloscope that is set to average consecutive pulses 48 times for noise reduction of the hydrophone output. A commercial transmitter unit is used to drive the transducer with a 10 cycle tone burst at a frequency of 4.0 MHz and a maximum excitation amplitude of 31 volt.ResultsPredictions using the ZR give a pressure pulse error (PPE) and an intensity error (IE) of 32 % and 23 %, respectively, relative to the measured. Altering the piezoelectric permittivity +12 % from ZR decreases the PPE to 30 % and the IE to 2 % relative to the measured. Changing the stiffness constant of the lens -4 % from ZR increases the PPE and the IE with 6 % and 1 %, respectively. Performing the same with the ceramic stiffness the PPE is lowered 1.5 % and the IE is lowered 12 %.Discussion and ConclusionsPPEs are found mainly to be sensitive to lens properties and piezoceramic properties, but minor sensitive to changes in matching layers. IEs are mainly sensitive to the piezoceramic properties. The study shows that minor changes can improve predictions significantly.
    Original languageEnglish
    Title of host publication2009 IEEE International Ultrasonics Symposium (IUS)
    Number of pages4
    PublisherIEEE
    Publication date2009
    ISBN (Print)978-1-4244-4389-5
    ISBN (Electronic)978-1-4244-4390-1
    DOIs
    Publication statusPublished - 2009
    EventIEEE International Ultrasoincs Symposium (IUS) - Rome, Italy
    Duration: 20 Sept 200923 Sept 2009

    Conference

    ConferenceIEEE International Ultrasoincs Symposium (IUS)
    Country/TerritoryItaly
    CityRome
    Period20/09/200923/09/2009

    Bibliographical note

    Copyright 2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.

    Keywords

    • Transducer modeling
    • Field II
    • Sensitivity study
    • piezo

    Fingerprint

    Dive into the research topics of 'Parameter sensitivity study of a Field II multilayer transducer model on a convex transducer'. Together they form a unique fingerprint.

    Cite this