Optimisation of Control Strategy at the Central Solar Heating Plant in Marstal, Denmark

Alfred Heller

    Research output: Book/ReportReportResearchpeer-review

    Abstract

    The central solar heating plant at Marstal is monitored since 1996. The data is analysed with focus on the applied constrol strategy for the solar collector field. Variable flow is applied which is not the case at the other plants compared. The project analysed the performance, compared the performance with other control strategies and made proposals for furher enhancements.
    Original languageDanish
    Number of pages38
    Publication statusPublished - 1999

    Cite this

    @book{226f42aef8e6495aade562cb8d26db1f,
    title = "Optimisation of Control Strategy at the Central Solar Heating Plant in Marstal, Denmark",
    abstract = "The central solar heating plant at Marstal is monitored since 1996. The data is analysed with focus on the applied constrol strategy for the solar collector field. Variable flow is applied which is not the case at the other plants compared. The project analysed the performance, compared the performance with other control strategies and made proposals for furher enhancements.",
    author = "Alfred Heller",
    year = "1999",
    language = "Dansk",

    }

    Optimisation of Control Strategy at the Central Solar Heating Plant in Marstal, Denmark. / Heller, Alfred.

    1999. 38 p.

    Research output: Book/ReportReportResearchpeer-review

    TY - RPRT

    T1 - Optimisation of Control Strategy at the Central Solar Heating Plant in Marstal, Denmark

    AU - Heller, Alfred

    PY - 1999

    Y1 - 1999

    N2 - The central solar heating plant at Marstal is monitored since 1996. The data is analysed with focus on the applied constrol strategy for the solar collector field. Variable flow is applied which is not the case at the other plants compared. The project analysed the performance, compared the performance with other control strategies and made proposals for furher enhancements.

    AB - The central solar heating plant at Marstal is monitored since 1996. The data is analysed with focus on the applied constrol strategy for the solar collector field. Variable flow is applied which is not the case at the other plants compared. The project analysed the performance, compared the performance with other control strategies and made proposals for furher enhancements.

    M3 - Rapport

    BT - Optimisation of Control Strategy at the Central Solar Heating Plant in Marstal, Denmark

    ER -