Abstract
This paper presents a new PWM method and commutation strategy for
HF-link converters, which leads to safe commutation of the load
current in the output bidirectional bridge. The proposed
implementation is independent of the particular HF-link converter
topology and bidirectional switch selection and is therefore
usable at all output power levels and switching frequencies.
Theoretical analysis of the approach and experimental
investigation are presented to prove the feasibility of the
concept.