Natural convection in sheep's wool and paper insulation: Part of technical heat and moisture investigations of alternative insulation materials

Finn Harken Kristiansen, Carsten Rode

    Research output: Book/ReportReportpeer-review

    Abstract

    The natural convection of two types of alternative insulation material has been measured in the convection apparatus of Department of Buildings and Energy. Measurements have been made on a type of sheep's wool (Herawool) with support fibres from the firm of Heraklith and a type of paper insulation (Ekofiber Vind) from Ekofiber. The density of the sheep's wool was 28 kg/m3 and the paper insulation was 65 kg/m3. The temperature on the hot side of the test specimen was 30°C and on the cold side ca. -10°C, that is a temperature difference over the test specimen of ca. 40 K.The measurements on the two alternative insulation materials have been compared to previous measurements on a traditional insulation material (Rockwool).Calculations of the convection conditions in the two materials have been made by means of a computer program CHConP. The measurements have been compared with these calculations.
    Original languageDanish
    Number of pages29
    Publication statusPublished - 1999

    Cite this