Linear accelerator radiography

J. Domanus, J. Hansen

    Research output: Book/ReportReportResearch

    72 Downloads (Pure)

    Abstract

    A description is given of the Risø lo MeV linear accelerator, which was used for radiography of steel (50 to 250 mm thick). Different X-ray film and intensifying screen combinations were tested and characteristic curves and exposure charts were computed. X-ray film speed and contrast were calculated. Radiographic image contrast and quality were investigated and the best combination of X-ray film and screen was chosen. Conclusions were drawn about the possibility of using the Risø accelerator for industrial radiography.