Abstract
For hydrodynamic examinations of the turbid three-phase streams with air bubbles and with a depth more than 500 mm for the first time it is developed 2D Laser Doppler Semiconductor Anemometer LADO5-LMZ. Anemometer signal processor base on > and new procedure of adaptive selection of Doppler frequency. Complex testing of method and measuring tools have been done. Outcomes of full-scale experiments on diagnostic of nonstationary flow behind the vane wheel rotor in draught tube of the Frensis water turbine are presented from optimum regimes of activity to forced. Water discharge which has been calculated from water turbine universal performance model and calculated by measuring axial velocity profiles was compared. It is shown that the maximum aggregate error of definition of the consumption does not exceed 5%.
Original language | English |
---|---|
Journal | Proceedings of SPIE - The International Society for Optical Engineering |
Pages (from-to) | 62620G |
ISSN | 0277-786X |
DOIs | |
Publication status | Published - 2006 |
Externally published | Yes |
Event | Optical Methods of Flow Investigation - Duration: 1 Jan 2006 → … |
Conference
Conference | Optical Methods of Flow Investigation |
---|---|
Period | 01/01/2006 → … |