Abstract

Utilizing a fatigue-rated multi-axial strong-floor based test rig, the effect of a retro-fitted fish-mouth third shear-web geometry detail located within the double-curved trailing edge sandwich panels are evaluated in an inner 15m root section from a 34m wind turbine blade manufactured by SSP Technology. From previous research, a load configuration is identified, capable of triggering the breathing/pumping deformations in the trailing edge panels within the root and transition zone, which will drive the propagation on the shear-web disbonding mechanism. Investigation and evaluation of the shear web disbonding and associated mitigation are acquired through strain gauges, wire potentiometer and digital image correlation (DIC) measurements inside the root section.
Original languageEnglish
Article number012026
JournalIOP Conference Series: Materials Science and Engineering
Volume1293
Issue number1
Number of pages10
ISSN1757-8981
DOIs
Publication statusPublished - 2023

Fingerprint