Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good agreement with the measured efficiencies.
Original languageEnglish
Title of host publicationProceedings of the 1st Solar District Heating Conference
Number of pages5
Publication date2013
Publication statusPublished - 2013
Event1st Solar District Heating Conference - Malmö, Sweden
Duration: 9 Apr 201310 Apr 2013

Conference

Conference1st Solar District Heating Conference
CountrySweden
CityMalmö
Period09/04/201310/04/2013

Cite this

@inproceedings{d7a19079380646b09441984f836d69a4,
title = "Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts",
abstract = "Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good agreement with the measured efficiencies.",
author = "Ziqian Chen and Bengt Perers and Simon Furbo and Jianhua Fan",
year = "2013",
language = "English",
booktitle = "Proceedings of the 1st Solar District Heating Conference",

}

Chen, Z, Perers, B, Furbo, S & Fan, J 2013, Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts. in Proceedings of the 1st Solar District Heating Conference. 1st Solar District Heating Conference, Malmö, Sweden, 09/04/2013.

Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts. / Chen, Ziqian; Perers, Bengt; Furbo, Simon; Fan, Jianhua.

Proceedings of the 1st Solar District Heating Conference. 2013.

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

TY - GEN

T1 - Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts

AU - Chen, Ziqian

AU - Perers, Bengt

AU - Furbo, Simon

AU - Fan, Jianhua

PY - 2013

Y1 - 2013

N2 - Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good agreement with the measured efficiencies.

AB - Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good agreement with the measured efficiencies.

M3 - Article in proceedings

BT - Proceedings of the 1st Solar District Heating Conference

ER -