Skip to main navigation Skip to search Skip to main content

Investigation of electrochemical migration and dendrite formation mechanism in electronics from low to high voltage

Research output: Book/Report › Ph.D. thesis

11 Downloads (Orbit)

Abstract

This PhD project was supported by the CreCon consortium (Industrial Consortium for Climatically Reliable Electronics) which focused on understanding the modification of corrosion failure mechanisms in electronic devices from low to high voltage operating systems. This is of great importance as the trend towards the use of high voltage/power devices is significantly increasing. The motivation of this PhD thesis is to provide a holistic understanding of humidity-driven corrosion failure especially leak current and Electrochemical Migration (ECM) on high voltage PCBs, starting from formation of condensed water film dynamics, reactions in the formed corrosion cell and different failure mechanisms (ECM, Anodic Migration Phenomenon (AMP), thermal effects) due to the formed corrosion products. The understanding of droplet morphology and coalescence with varying parameters such as voltages and undercooling temperatures was investigated. This was taken a step further by looking into the effect of changing orientations under condensing conditions, on droplet dynamics and ECM-related failures. A deep understanding of the kinetics of various electrochemical reactions defining the chemistry and morphology of changing corrosion products was studied. Furthermore, formation of varying nature of the corrosion products with increasing applied voltage and thermal release associated with this growth was investigated. The combined investigation of the kinetics involved, changes in the growing dendritic morphologies and subsequent thermal release under high voltage was studied. Experimental methods include galvanostatic and potentiostatic electrochemical methods and materials characterization methods such as SEM, EDX, LOM, ICP-OES and XPS. Chapter 1 provides a general introduction consisting of background, motivation and scope of this PhD thesis. Chapter 2 summarizes the available literature connected to this thesis. Chapter 3 presents the summary of all the materials and methods, including the test PCB structures, experimental methods and characterization techniques, employed in this thesis. Chapter 4 provides a summary of appended papers highlighting the objectives and findings from each of the appended papers presented in the following chapters. The main studies carried out as a part of this thesis are contained in chapters 5-9, presented as full papers that are either published in journals after peer-review or as ready manuscripts to be submitted to peer-reviewed journals. Among the appended papers, Chapter 5 investigates the effect of applied voltages and undercooling temperatures under condensing conditions causing ECM. Chapter 6 looks into the droplet dynamics under condensing conditions as a function of varying orientation (horizontal, vertical and angled) of the samples. The kinetics of various electrochemical reactions and growth characteristics of the corrosion products under a water film is presented in Chapter 7. The thermal release during dendrite shorting due to electrical discharge as a function of increasing applied voltage and growing dendrite corrosion products is contained in Chapter 8. Finally, chapter 9 investigates the changing morphology of the dendrites during ECM under high voltages in electronic devices. Chapters 10, 11 and 12 provide an overall discussion highlighting the main findings from each appended paper, overall conclusions from all the studies and suggestions for future work. The first study (Chapter 5) focuses on the growing droplet morphology and subsequent coalescence under continuous condensation on a PCB surface, under varying applied voltages and undercooling temperatures. The effect of varying undercooling is evident where a higher ΔT leads to faster droplet formation and coalescence compared to a lower ΔT. After coalescence, leakage current and dendritic growth are governed by voltage-driven kinetics. As devices are seldom constrained to a single orientation, the next study (Chapter 6) explores how PCB orientation impacts ECM under condensing conditions. The horizontally oriented sample consists of stable corrosion cells, leading to faster ECM and heavy corrosion. When samples are placed vertically or at an angle, gravitational force combined with surface tension affects the stability of the micro-electrochemical cells formed which either leads to removal of droplets without significant influence on leak current or ECM formation unlike for the horizontal placement. With the droplet growth and coalescence connection to the leak current and ECM development was established, Chapters 7–9 examine the kinetics of electrochemical reactions that determine corrosion product chemistry and morphology, under the presence of pure water. Chapter 7 shows that conductivity of this water film gradually increases with the release of Cux+/H+ and OH- ions at the anode and cathode respectively. This additionally creates a pH gradient that determines the stability of copper ions in the electrolyte. Depending on local pH and increasing Cux+ ion concentration, oxides and hydroxides form along with metallic dendrites. Chapter 8 shows that increasing applied voltage increases recorded temperature due to resistive heating within dendrites and mixed corrosion products. At lower voltages, thin metallic dendrites behave like pure resistors and lead to a gradual (lower) temperature rise. On the other hand, with increasing voltages, the growing amount of semiconductive oxides and hydroxides introduces greater resistance and higher localized heating. This results in higher recorded temperatures, which can potentially lead to fire in electronic devices in operation. Chapter 9 highlights the strong influence of electric field at higher applied voltages. The corrosion product morphology shifts from a uniform dendritic growth along the electrode surface (at 200 V) to vigorous bubbling associated with increased rate of hydrolysis reaction (at 1600 V). The results from COMSOL adds to the understanding that increasing the applied voltage influences the electric field and forming dendrite thickness. Additionally, the importance of current in the development of ECM dendrite was shown, which is important in connection with humidity testing for which sometime current control is employed.
Original languageEnglish
PublisherTechnical University of Denmark
Number of pages258
Publication statusPublished - 2026

Fingerprint

Dive into the research topics of 'Investigation of electrochemical migration and dendrite formation mechanism in electronics from low to high voltage'. Together they form a unique fingerprint.

Cite this