Interobserver delineation variation in lung tumour stereotacticbody radiotherapy

G. F. Persson, D. E. Nygaard, Christian Hollensen, P. Munck af Rosenschöld, L. S. Mouritsen, A. K. Due, A. K. Berthelsen, J. Nyman, E. Markova, A. P. Roed, H. Roed, S. Korreman, L. Specht

    Research output: Contribution to journalJournal articleResearchpeer-review

    Abstract

    Objectives
    In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design.
    Methods
    22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SDtrans) and craniocaudal (CC) direction (SDcc) separately. Concordance indexes and volume deviations were also calculated.
    Results
    Median tumour volume was 13.0 cm3, ranging from 0.3 to 60.4 cm3. The mean SDtrans was 0.15 cm (SD 0.08 cm) and the overall mean SDcc was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SDtrans than tumours surrounded by lung tissue.
    Conclusions
    The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours.
    Original languageEnglish
    JournalBritish Journal of Radiology
    Volume85
    Issue number1017
    Pages (from-to)e654-e660
    ISSN0007-1285
    DOIs
    Publication statusPublished - 2012

    Cite this

    Persson, G. F., Nygaard, D. E., Hollensen, C., Munck af Rosenschöld, P., Mouritsen, L. S., Due, A. K., Berthelsen, A. K., Nyman, J., Markova, E., Roed, A. P., Roed, H., Korreman, S., & Specht, L. (2012). Interobserver delineation variation in lung tumour stereotacticbody radiotherapy. British Journal of Radiology, 85(1017), e654-e660. https://doi.org/10.1259/bjr/76424694