Skip to main navigation Skip to search Skip to main content

Inter-laboratory comparison of water solubility methods applied to difficult-to-test substances

    • ExxonMobil

    Research output: Contribution to journal › Journal article › Research › peer-review

    255 Downloads (Orbit)

    Abstract

    Water solubility is perhaps the single most important physical–chemical property determining the environmental fate and effects of organic compounds. Its determination is particularly challenging for compounds with extremely low solubility, frequently referred to as “difficult-to-test” substances and having solubility’s generally less than 0.1 mg/L. The existing regulatory water solubility test for these compounds is the column elution method. Its applicability, however, is limited, to non-volatile solid or crystalline hydrophobic organic compounds. There currently exists no test guideline for measuring the water solubility of very hydrophobic liquid, and potentially volatile, difficult-to-test compounds. This paper describes a “slow-stir” water solubility methodology along with results of a ring trial across five laboratories evaluating the method’s performance. The slow-stir method was applied to n-hexylcyclohexane, a volatile, liquid hydrophobic hydrocarbon. In order to benchmark the inter-laboratory variability associated with the proposed slow-stir method, the five laboratories separately determined the solubility of dodecahydrotriphenylene, a hydrophobic solid compound using the existing column elution guideline. Results across the participating laboratories indicated comparable reproducibility with relative standard deviations (RSD) of 20% or less reported for each test compound – solubility method pair. The inter-laboratory RSD was 16% for n-hexylcyclohexane (mean 14 µg/L, n = 5) using the slow-stir method. For dodecahydrotriphenylene, the inter-laboratory RSD was 20% (mean 2.6 µg/L, n = 4) using the existing column elution method. This study outlines approaches that should be followed and the experimental parameters that have been deemed important for an expanded ring trial of the slow-stir water solubility method. [Figure not available: see fulltext.].

    Original languageEnglish
    Article number52
    JournalBMC Chemistry
    Volume15
    Issue number1
    Number of pages10
    ISSN2661-801X
    DOIs
    Publication statusPublished - 2021

    Bibliographical note

    © The Author(s) 2021. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/. The Creative Commons Public Domain Dedication waiver
    (http://creativecommons.org/publicdoma in/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

    Keywords

    • Difficult-to-test
    • Generator column
    • Hydrophobic organics
    • Ring test
    • Slow-stir method
    • Volatile
    • Water solubility

    Fingerprint

    Dive into the research topics of 'Inter-laboratory comparison of water solubility methods applied to difficult-to-test substances'. Together they form a unique fingerprint.

    Cite this