Abstract
This paper describes the fabrication and testing of Mg-doped SrTiO3 thick-film oxygen sensors with an integrated Pt heater. The results show that the sensor exhibits a PO2 dependence according to R proportional to PO2-1/4 in the considered PO2 range(2.5 x 10(-5) bar <PO2< 0.21 bar) and a response and recovery time of 1-2 and 50 s respectively. A temperature of 600 degrees C could be reached by a relative low power comsumption of the Pt heater.
Original language | English |
---|---|
Title of host publication | Technical Digest of the Seventh International Meeting on Chemical sensors |
Place of Publication | Beijing |
Publisher | International Academic Publishers |
Publication date | 1998 |
Pages | 437-439 |
ISBN (Print) | 7-80003-423-2 |
Publication status | Published - 1998 |
Event | 7th International Meeting on Chemical Sensors - Beijing, China Duration: 27 Jul 1998 → 30 Jul 1998 Conference number: 7 |
Conference
Conference | 7th International Meeting on Chemical Sensors |
---|---|
Number | 7 |
Country/Territory | China |
City | Beijing |
Period | 27/07/1998 → 30/07/1998 |