    Abstract

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed
    with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure
    charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings,
    assemblies, etc.
    Original languageEnglish
    Place of PublicationRoskilde, Denmark
    PublisherRisø National Laboratory
    Number of pages153
    ISBN (Print)87-550-0504-7
    Publication statusPublished - 1977
    SeriesDenmark. Forskningscenter Risoe. Risoe-R
    Number371
    ISSN0106-2840

    Keywords

    • Risø-R-371
    • Risø-371
    • Risø report 371

    Fingerprint Dive into the research topics of 'Industrial radiography on radiographic paper'. Together they form a unique fingerprint.