Incompatibility between Zircaloy-2 and Inconel X-750 during Temperature Transients

M. R. Warren, Kaj Rørbo, Eivind Adolph

    Research output: Contribution to journalJournal articleResearchpeer-review

    Abstract

    The incompatibility of Zircaloy-2 and Inconel X-750 has been investigated between 1000°C and 1200°C (1200°C being the currently allowable maximum temperature in the acceptance criteria for ECCS for water reactors). It has been found for the temperatures of 1000°C and 1200°C that oxide thicknesses of 2 and 30 μ respectively protect the Zircaloy-2 against attack by Inconel X-750.
    Original languageEnglish
    JournalJournal of Nuclear Materials
    Volume58
    Issue number2
    Pages (from-to)185-188
    ISSN0022-3115
    DOIs
    Publication statusPublished - 1975