Abstract
We consider optimized configurations of high-contrast one-dimensional sub-wavelength gratings as label-free biosensors for proteins detection. Parameters of the sensors, in particular sensitivity, are improved in comparison with the basic design. Modeling was done by three numerical methods providing required reproducibility and convergence.
Original language | English |
---|---|
Publication date | 2021 |
DOIs | |
Publication status | Published - 2021 |
Event | Optical Sensors 2021 - Washington, United States Duration: 19 Jul 2021 → 23 Jul 2021 |
Conference
Conference | Optical Sensors 2021 |
---|---|
Country/Territory | United States |
City | Washington |
Period | 19/07/2021 → 23/07/2021 |