Abstract
The merit of activated sludge models depends on the accuracy and reliability of the information
they contain on the wastewater to be treated and the biochemical mechanisms involved. In most advanced
calibration studies, respirometry i.e. the measurement of the oxygen utilization rate, (OUR), provides the
majority of the required experimental database. However, currently used procedures still involve a number of
basic and practical problems. Model evaluation of the OUR data may generate a distorted image of the
processes involved. Hydrolysis is the most important, yet the most vulnerable process as far as the
experimental assessment of accurate kinetic parameters is concerned. This study intends to provide an
overview of major experimental limitations in the modeling of activated sludge, with emphasis on the
appropriate experimental design for the assessment of the hydrolysis rate.
Original language | English |
---|---|
Journal | Water Science and Technology |
Volume | 45 |
Issue number | 12 |
Pages (from-to) | 23-36 |
ISSN | 0273-1223 |
Publication status | Published - 2002 |
Keywords
- respirometry
- endogenous decay
- Active biomass
- model sensitivity
- model parameters
- hydrolysis
- experimental analysis
- activated sludge
- process kinetics