@book{dd5b670ee35c4e9da08edf9f44adc419,
title = "Impact of advanced wind power ancillary services on power system",
abstract = "The objective of this report is to illustrate and analyse, by means of simulation test cases, the impact of wind power advanced ancillary services, like inertial response (IR), power oscillation damping (POD) and synchronising power (SP) on the power system. Generic models for wind turbine, wind power plant and power system are used in the investigation.",
keywords = "DTU Wind Energy E-0081, DTU Wind Energy E-81",
author = "Hansen, \{Anca Daniela\} and M{\"u}fit Altin",
note = "This report is elaborated as part of the work done in the project titled {\textquotedblleft}Enhance ancillary services from wind power{\textquotedblright} (EaseWind). The project was funded by the Danish TSO as PSO project 2011 no. 10653, and it was carried out in collaboration between Vestas Wind System A/S, DTU Wind Energy, DTU Compute and Aalborg University IET. Vestas Wind System A/S has been the manager of the project. The report has been internally reviewed and approved by Vestas and Aalborg University IET.",
year = "2015",
language = "English",
series = "DTU Wind Energy E",
number = "0081",
publisher = "DTU Wind Energy",
address = "Denmark",
}