Hydrodynamics of the leucon sponge pump

Seyed Saeed Asadzadeh, Poul S. Larsen, Hans Ulrik Riisgård, Jens H. Walther*

*Corresponding author for this work

    Research output: Contribution to journalJournal articleResearchpeer-review

    190 Downloads (Orbit)

    Abstract

    Leuconoid sponges are filter-feeders with a complex system of branching inhalant and exhalant canals leading to and from the close-packed choanocyte chambers. Each of these choanocyte chambers holds many choanocytes that act as pumping units delivering the relatively high pressure rise needed to overcome the system pressure losses in canals and constrictions. Here, we test the hypothesis that, in order to deliver the high pressures observed, each choanocyte operates as a leaky, positive displacement-type pump owing to the interaction between its beating flagellar vane and the collar, open at the base for inflow but sealed above. The leaking backflow is caused by small gaps between the vaned flagellum and the collar. The choanocyte pumps act in parallel, each delivering the same high pressure, because low-pressure and high-pressure zones in the choanocyte chamber are separated by a seal (secondary reticulum). A simple analytical model is derived for the pump characteristic, and by imposing an estimated system characteristic we obtain the back-pressure characteristic that shows good agreement with available experimental data. Computational fluid dynamics is used to verify a simple model for the dependence of leak flow through gaps in a conceptual collar–vane–flagellum system and then applied to models of a choanocyte tailored to the parameters of the freshwater demosponge Spongilla lacustris to study its flows in detail. It is found that both the impermeable glycocalyx mesh covering the upper part of the collar and the secondary reticulum are indispensable features for the choanocyte pump to deliver the observed high pressures. Finally, the mechanical pump power expended by the beating flagellum is compared with the useful (reversible) pumping power received by the water flow to arrive at a typical mechanical pump efficiency of about 70%.
    Original languageEnglish
    Article number20180630
    JournalJournal of the Royal Society. Interface
    Volume16
    Issue number150
    Number of pages9
    ISSN1742-5689
    DOIs
    Publication statusPublished - 2019

    Keywords

    • Choanocytes
    • Flagellar vane
    • Low Reynolds number flow
    • Computational fluid dynamics
    • Positive displacement pump

    Fingerprint

    Dive into the research topics of 'Hydrodynamics of the leucon sponge pump'. Together they form a unique fingerprint.

    Cite this