TY - BOOK
T1 - Hybrid microscale analytical methods for environmental analysis
AU - Lafleur, Josiane P.
A2 - Salin, Eric D.
PY - 2009
Y1 - 2009
N2 - The contamination of natural resources by human activity can have severe
socio-economical impacts. Environmental analytical chemistry plays an essential
role in the solving of these environmental problems. However, conventional
environmental analytical procedures are generally lengthy and necessitate
several steps. Hybrid microscale analytical techniques have been developed with
the objective of minimizing the number of sample preparation steps, avoiding the
use of organic solvents and reducing the size of the samples required for an
analysis as well as increasing the speed of analyses.
An Inductively Heated – Electrothermal Vaporizer (IH-ETV) was coupled to
an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) to vaporize
mercury from single human hair strands without any prior sample preparation,
such as the destruction of its matrix by digestion. The results were comparable to
those obtained with a reference method.
For samples requiring chromatographic separation, sample handling was
minimized by direct coupling of the chromatographic procedure to an ICP-MS
through Laser Ablation (LA). Cr3+ and Cr6+ were separated on silica gel High
Performance Thin Layer Chromatography plates (HPTLC) using aqueous mobile
phases. LA was used to volatilize the chromium species directly from thechromatographic stationary phase material for ICP-MS detection. This procedure
allows for a rapid separation and quantification, and requires only 0.5 μL of sample.
The same procedure was used to couple miniature Solid Phase Extraction
(SPE) columns implemented on centrifugal microfluidic discs to an ICP-MS to
determine pre-concentrated metal chelates from drinking water. The miniature
SPE devices require only 1 – 600 μL samples, allowing a reduction of three to four
orders of magnitude in sample size compared to the conventional procedure, and
the device requires no more than a simple motor to actuate fluid flow. The centrifugal
microfluidic SPE discs can be used to perform up to eight extractions simultaneously
and allow the easy storage of samples before transport to the laboratory for LA-ICPMS
analysis.
Finally, the centrifugal microfluidic SPE discs were modified to allow their
coupling to absorption and fluorescence spectrometers. As well as the
advantages listed above, this hyphenated system allows the in-situ screening of
aquatic organic pollutants trapped on the SPE column directly in the field using
simple and small light sources and detectors.
AB - The contamination of natural resources by human activity can have severe
socio-economical impacts. Environmental analytical chemistry plays an essential
role in the solving of these environmental problems. However, conventional
environmental analytical procedures are generally lengthy and necessitate
several steps. Hybrid microscale analytical techniques have been developed with
the objective of minimizing the number of sample preparation steps, avoiding the
use of organic solvents and reducing the size of the samples required for an
analysis as well as increasing the speed of analyses.
An Inductively Heated – Electrothermal Vaporizer (IH-ETV) was coupled to
an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) to vaporize
mercury from single human hair strands without any prior sample preparation,
such as the destruction of its matrix by digestion. The results were comparable to
those obtained with a reference method.
For samples requiring chromatographic separation, sample handling was
minimized by direct coupling of the chromatographic procedure to an ICP-MS
through Laser Ablation (LA). Cr3+ and Cr6+ were separated on silica gel High
Performance Thin Layer Chromatography plates (HPTLC) using aqueous mobile
phases. LA was used to volatilize the chromium species directly from thechromatographic stationary phase material for ICP-MS detection. This procedure
allows for a rapid separation and quantification, and requires only 0.5 μL of sample.
The same procedure was used to couple miniature Solid Phase Extraction
(SPE) columns implemented on centrifugal microfluidic discs to an ICP-MS to
determine pre-concentrated metal chelates from drinking water. The miniature
SPE devices require only 1 – 600 μL samples, allowing a reduction of three to four
orders of magnitude in sample size compared to the conventional procedure, and
the device requires no more than a simple motor to actuate fluid flow. The centrifugal
microfluidic SPE discs can be used to perform up to eight extractions simultaneously
and allow the easy storage of samples before transport to the laboratory for LA-ICPMS
analysis.
Finally, the centrifugal microfluidic SPE discs were modified to allow their
coupling to absorption and fluorescence spectrometers. As well as the
advantages listed above, this hyphenated system allows the in-situ screening of
aquatic organic pollutants trapped on the SPE column directly in the field using
simple and small light sources and detectors.
M3 - Ph.D. thesis
BT - Hybrid microscale analytical methods for environmental analysis
ER -