Heat transfer corrected isothermal model for devolatilization of thermally-thick biomass particles

Research output: Contribution to conferencePaper – Annual report year: 2017Researchpeer-review

Documents

View graph of relations

Isothermal model used in current computational fluid dynamic (CFD) model neglect the internal heat transfer during biomass devolatilization. This assumption is not reasonable for thermally-thick particles. To solve this issue, a heat transfer corrected isothermal model is introduced. In this model, two heat transfer corrected coefficients: HT-correction of heat transfer and HR-correction of reaction, are defined to cover the effects of internal heat transfer. A series of single biomass devitalization case have been modeled to validate this model, the results show that devolatilization behaviors of both thermally-thick and thermally-thin particles are predicted reasonable by using heat transfer corrected model, while, isothermal model overestimate devolatilization rate and heating rate for thermlly-thick particle.This model probably has better performance than isothermal model when it is coupled with CFD to model devolatilization of thermally-thick biomass particles.
Original languageEnglish
Publication date2017
Number of pages12
Publication statusPublished - 2017
EventNordic Flame Days - KTH - The Royal Institute of Technology , Stockholm, Sweden
Duration: 10 Oct 201711 Oct 2017

Conference

ConferenceNordic Flame Days
LocationKTH - The Royal Institute of Technology
CountrySweden
CityStockholm
Period10/10/201711/10/2017