Abstract

In power performance testing, it has been demonstrated that the effects of wind speed and direction variations over the rotor disk can no longer be neglected for large wind turbines [1]. A new generation of commercial nacelle-based lidars is now available, offering wind profiling capabilities. Developing standard procedures for power curves using lidars requires assessing lidars measurement uncertainty that is provided by a calibration. Based on the calibration results from two lidars, the Avent 5-beam Demonstrator and the Zephir Dual Mode (ZDM), we present in this paper a generic methodology to calibrate profiling nacelle lidars.
Original languageEnglish
Publication date2015
Number of pages4
Publication statusPublished - 2015
Event12th German Wind Energy Conference - Bremen, Germany
Duration: 19 May 201520 May 2015
Conference number: 12
http://www.dewek.de/

Conference

Conference12th German Wind Energy Conference
Number12
CountryGermany
CityBremen
Period19/05/201520/05/2015
Internet address

Cite this

Borraccino, A., Courtney, M., & Wagner, R. (2015). Generic calibration procedures for nacelle-based profiling lidars. Paper presented at 12th German Wind Energy Conference, Bremen, Germany.
Borraccino, Antoine ; Courtney, Michael ; Wagner, Rozenn. / Generic calibration procedures for nacelle-based profiling lidars. Paper presented at 12th German Wind Energy Conference, Bremen, Germany.4 p.
@conference{99354b5587f947c38fab447f537e1d81,
title = "Generic calibration procedures for nacelle-based profiling lidars",
abstract = "In power performance testing, it has been demonstrated that the effects of wind speed and direction variations over the rotor disk can no longer be neglected for large wind turbines [1]. A new generation of commercial nacelle-based lidars is now available, offering wind profiling capabilities. Developing standard procedures for power curves using lidars requires assessing lidars measurement uncertainty that is provided by a calibration. Based on the calibration results from two lidars, the Avent 5-beam Demonstrator and the Zephir Dual Mode (ZDM), we present in this paper a generic methodology to calibrate profiling nacelle lidars.",
author = "Antoine Borraccino and Michael Courtney and Rozenn Wagner",
year = "2015",
language = "English",
note = "12th German Wind Energy Conference, DEWEK ; Conference date: 19-05-2015 Through 20-05-2015",
url = "http://www.dewek.de/",

}

Borraccino, A, Courtney, M & Wagner, R 2015, 'Generic calibration procedures for nacelle-based profiling lidars', Paper presented at 12th German Wind Energy Conference, Bremen, Germany, 19/05/2015 - 20/05/2015.

Generic calibration procedures for nacelle-based profiling lidars. / Borraccino, Antoine; Courtney, Michael; Wagner, Rozenn.

2015. Paper presented at 12th German Wind Energy Conference, Bremen, Germany.

Research output: Contribution to conferencePaperResearchpeer-review

TY - CONF

T1 - Generic calibration procedures for nacelle-based profiling lidars

AU - Borraccino, Antoine

AU - Courtney, Michael

AU - Wagner, Rozenn

PY - 2015

Y1 - 2015

N2 - In power performance testing, it has been demonstrated that the effects of wind speed and direction variations over the rotor disk can no longer be neglected for large wind turbines [1]. A new generation of commercial nacelle-based lidars is now available, offering wind profiling capabilities. Developing standard procedures for power curves using lidars requires assessing lidars measurement uncertainty that is provided by a calibration. Based on the calibration results from two lidars, the Avent 5-beam Demonstrator and the Zephir Dual Mode (ZDM), we present in this paper a generic methodology to calibrate profiling nacelle lidars.

AB - In power performance testing, it has been demonstrated that the effects of wind speed and direction variations over the rotor disk can no longer be neglected for large wind turbines [1]. A new generation of commercial nacelle-based lidars is now available, offering wind profiling capabilities. Developing standard procedures for power curves using lidars requires assessing lidars measurement uncertainty that is provided by a calibration. Based on the calibration results from two lidars, the Avent 5-beam Demonstrator and the Zephir Dual Mode (ZDM), we present in this paper a generic methodology to calibrate profiling nacelle lidars.

M3 - Paper

ER -

Borraccino A, Courtney M, Wagner R. Generic calibration procedures for nacelle-based profiling lidars. 2015. Paper presented at 12th German Wind Energy Conference, Bremen, Germany.