Fast Spectral Velocity Estimation Using Adaptive Techniques: In-Vivo Results

Fredrik Gran, Andreas Jakobsson, Jesper Udesen, Jørgen Arendt Jensen

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    541 Downloads (Pure)

    Abstract

    Adaptive spectral estimation techniques are known to provide good spectral resolution and contrast even when the observation window(OW) is very sbort. In this paper two adaptive techniques are tested and compared to the averaged perlodogram (Welch) for blood velocity estimation. The Blood Power spectral Capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slowtime and depth. The Blood Amplitude and Phase Estimation technique (BAPES) is based on finding a set of matched filters (one for each velocity component of interest) and filtering the blood process over slow-time and averaging over depth to find the power spectral density estimate. In this paper, the two adaptive methods are explained, and performance Is assessed in controlled steady How experiments and in-vivo measurements. The three methods were tested on a circulating How rig with a blood mimicking fluid flowing in the tube. The scanning section is submerged in water to allow ultrasound data acquisition. Data was recorded using a BK8804 linear array transducer and the RASMUS ultrasound scanner. The controlled experiments showed that the OW could be significantly reduced when applying the adaptive methods without compromising spectral resolution or contrast. The in-vivo data was acquired using a BK8812 transducer. OWs of 128, 64, 32 and 16 slow- time samples were tested. Spectrograms with duration of 2 seconds were generated. Welch's method required 128 samples to give a reasonable spectrogram, whereas the BPC only required 32 samples before the SNR became a limiting factor. The BAPES managed to display the spectrogram with sufficient quality at 16 slow-time samples.
    Original languageEnglish
    Title of host publicationIEEE Ultrasonics Symposium, 2007
    PublisherIEEE
    Publication date2007
    Pages993-996
    ISBN (Print)978-1-4244-1384-3
    DOIs
    Publication statusPublished - 2007
    Event2007 IEEE Ultrasonics Symposium - New York, United States
    Duration: 28 Oct 200731 Oct 2007
    https://ieeexplore.ieee.org/xpl/conhome/4409572/proceeding

    Conference

    Conference2007 IEEE Ultrasonics Symposium
    Country/TerritoryUnited States
    CityNew York
    Period28/10/200731/10/2007
    Internet address

    Bibliographical note

    Copyright: 2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE

    Fingerprint

    Dive into the research topics of 'Fast Spectral Velocity Estimation Using Adaptive Techniques: In-Vivo Results'. Together they form a unique fingerprint.

    Cite this