TY - JOUR
T1 - Fast horizontal radial plume mapping of N2O using open-path absorption spectroscopy with a quantum-cascade laser
AU - Rodrigo, Peter John
AU - Larsen, Henning E.
AU - Ashik, A.S.
AU - Vechi, Nathalia Thygsen
AU - Kissas, Konstantinos
AU - Fredenslund, Anders Michael
AU - Scheutz, Charlotte
AU - Pedersen, Christian
PY - 2024
Y1 - 2024
N2 - We demonstrate record fast horizontal radial plume mapping (HRPM) of nitrous oxide (N2O) emissions, enabled by a quantum-cascade laser (QCL) and an open-path direct absorption spectroscopy operating around the 4.5 μm wavelength. The high signal-to-noise ratio of the system yields an atmospheric N2O sensor with a remarkable sensitivity of 25 ppt at 1 Hz update rate as assessed through Allan deviation analysis. The excellent sensitivity translates into significantly increased measurement rates (0.2−2 kHz) of column-integrated N2O concentrations. This is complemented by swift horizontal beam-scanning to multiple reflectors positioned in a 4 × 4 grid over a 735 m2 probed area. Consequently, we achieve HRPM over the probed area with scan times as short as 9 s, marking a substantial 60-fold improvement compared to a recent benchmark in the field. The exceptional data update rate of our QCL based sensor, coupled with the rapid beam-scanning capabilities, lays the foundation for real-time generation of HRPM tomographic maps of gas concentration with scan cycles on the order of 1 s. This presents a powerful tool for expedited gas leak source localization, as well as understanding the spatial dynamics of area source emissions.
AB - We demonstrate record fast horizontal radial plume mapping (HRPM) of nitrous oxide (N2O) emissions, enabled by a quantum-cascade laser (QCL) and an open-path direct absorption spectroscopy operating around the 4.5 μm wavelength. The high signal-to-noise ratio of the system yields an atmospheric N2O sensor with a remarkable sensitivity of 25 ppt at 1 Hz update rate as assessed through Allan deviation analysis. The excellent sensitivity translates into significantly increased measurement rates (0.2−2 kHz) of column-integrated N2O concentrations. This is complemented by swift horizontal beam-scanning to multiple reflectors positioned in a 4 × 4 grid over a 735 m2 probed area. Consequently, we achieve HRPM over the probed area with scan times as short as 9 s, marking a substantial 60-fold improvement compared to a recent benchmark in the field. The exceptional data update rate of our QCL based sensor, coupled with the rapid beam-scanning capabilities, lays the foundation for real-time generation of HRPM tomographic maps of gas concentration with scan cycles on the order of 1 s. This presents a powerful tool for expedited gas leak source localization, as well as understanding the spatial dynamics of area source emissions.
KW - Nitrous oxide
KW - Laser spectroscopy
KW - Standoff sensing
KW - Gas mapping
U2 - 10.1016/j.atmosenv.2024.120510
DO - 10.1016/j.atmosenv.2024.120510
M3 - Journal article
SN - 1352-2310
VL - 328
JO - Atmospheric Environment
JF - Atmospheric Environment
M1 - 120510
ER -