Skip to main navigation Skip to search Skip to main content

Evaluation of computational and physical parameters influencing CFD simulations of pollutant dispersion in building arrays

  • Yuwei Dai
  • , Cheuk Ming Mak*
  • , Zhengtao Ai
  • , Jian Hang
  • *Corresponding author for this work
    • Hong Kong Polytechnic University
    • Sun Yat-Sen University

    Research output: Contribution to journal › Journal article › Research › peer-review

    Abstract

    Many CFD studies have investigated the influence of computational parameters on the predicted concentrationdistribution of pollutants around isolated buildings, but such studies for building arrays are still lacking. Thisstudy systematically evaluated the influence of four computational and two physical parameters on pollutantdispersion in building arrays, including turbulence models, grid resolution, discretization of time step size Δt,length of sampling period, aspect ratio of the arrays, and release rate of tracer gas. Throughout these evaluations,a set of published wind tunnel experimental data was used to validate the CFD models. For concentration si-mulations, the Large Eddy Simulation (LES) model gave the most accurate results but still had limitations in areas near the source, whereas the Detached Eddy Simulation (DES) and the Reynolds Averaged Navier-Strokes (RANS) RNG k-ε models underperformed in some areas. The results of the LES and DES simulations varied with changes in Δt∗ and sampling length until Δt∗ was less than 0.24 and the sampling length was higher than 2400 Δt∗ or LES and 1200 Δt∗ for DES. A larger aspect ratio did not necessarily result in a higher concentration field than a smaller ratio. An increase in the tracer gas release rate did not change the general dispersion characteristics, but it still affected the concentration distribution in the areas near the source and resulted in a larger polluted area. The findings of this study are intended to contribute to improvements in the quality of CFD simulations of pollutant dispersion in building arrays.
    Original languageEnglish
    JournalBuilding and Environment
    Volume137
    Pages (from-to)90-107
    Number of pages18
    ISSN0360-1323
    DOIs
    Publication statusPublished - 2018

    Keywords

    • CFD simulation
    • Pollutant dispersion
    • Building arrays
    • Computational parameters
    • Sensitivity test

    Fingerprint

    Dive into the research topics of 'Evaluation of computational and physical parameters influencing CFD simulations of pollutant dispersion in building arrays'. Together they form a unique fingerprint.

    Cite this